Download Avaya BCM Management User Guide

Transcript
Chapter 2 Fault Management System
239
VoiceWatchdog
Return to table: Component ID (alarm)/eventSource (trap) summary
User action: Start this service manually. If unable to resolve the problem call for
Support. Voice Watchdog encountered the maximum limit of services
restarting times and the service needs to be restarted manually.
Alarm severity: Critical
Trap-type: Error
Logs: None
Event ID: 3003
Message: %Service Name% Start Service failed: The dependent service or
group failed to start.
User action: Start the root service of failed service manually. If unable to resolve
the problem call for Support
Alarm severity: Critical
Trap-type: Error
Logs: None
Comments: The service failed to start according to the failure in the root (parent)
service. The root service needs to be started manually.
Event ID: 3004
Message: %Service Name% Failed to start.
User action: Start this service manually. If unable to resolve the problem call for
Support.
Alarm severity: Critical
Trap-type: Error
Logs: None
Event ID: 3005
Message:
User action:
Alarm severity:
Trap-type:
Logs:
Service %Service Name% stopped unexpectedly.
Watchdog will restart this service, No action required.
Critical
Error
None
Business Communications Manager - Management User Guide