Download Kramer Electronics VS-162V video switch
Transcript
Connecting a Control Interface 2. Set DIP 7 ON (disabling null-modem adapter use1) on the VS-162V unit. 9.2 Connecting the RS-485 Control Interface Figure 15 defines the RS-485 connector pinout for external RS-485 control. The RS-485 connector is also used (if required) for vertical sync: Figure 15: RS-485 Connector PINOUT To connect an RS-485 connector on one VS-162V unit to an RS-485 connector on one or more other switchers (from the series of 16x16 matrix switchers), as Figure 16 illustrates: 1. Connect the “+” PIN on the first VS-162V unit to the “+” PIN on the second VS-162V unit or other unit 2. Connect the “-” PIN on the first VS-162V unit to the “-” PIN on the second VS-162V unit or other unit 3. If shielded cable is used for an RS-485 connection, connect the shield to the Ground PIN. For details about how to configure the vertical sync (if required), refer to section 9.3 and Figure 21 in section 11.5.1. 1 See section 8 26 KRAMER: SIMPLE CREATIVE TECHNOLOGY