Access Instructions by Draper
page 3 of 4
Case Dimensions
Mounting hardware
supplied by others
Mounting brackets slide
left and right as needed.
9"
1"
/16"
11
7"
65/8"
/16"
65/8"
11
21/8"
slot
L
8"
Series E or M
Access
L
Series E
7"
Series V Varies
Engagement bracket (one on each end
of the bottom access panel) clicks into
place with the ball detent on each endcap
Series V
Wiring Diagrams—110-120V Motor and Quiet Motor
13/16"
Please Note: Do not wire motors in parallel.
43/4"
21/8"
Limit Adjustments (Built-in Low Voltage Motors)
Single Station Control
Multiple Station Control
Please Note: Screen limits are factory set for optimum
Internal Screen Wiring
Internal Screen Wiring
performance of the screen. A procedure is outlined below for
White (Common)
White (Common)
minor tweaks, but any adjustment of these limits may negatively
Black (Down)
Black (Down)
affect the flatness of the screen surface and could also void the
Red (Up)
Red (Up)
warranty. Please check with Draper prior to resetting screen limits.
Green/Yellow (Ground)
Green/Yellow (Ground)
CAUTION: Always be prepared to shut screen off manually when
Cap off with wire
new adjustment is being tested. Screen may be severely damaged
Dashed wiring
nut and tape
by electrician
if viewing surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before
Control Single gang box by others
Red
Blue
adjusting limit switches.
switch
Min. 4" x 2 1/8" x 1 7/8" deep
Please note: When ordering a motor with built-in Low Voltage
Blue
Controller, if the case ships separate from the "guts," the case
Red
Black
Dashed wiring
Black
includes the 25' cable and special low voltage switch.
by electrician
1 Connect the ILT switch to the motor via the terminal blocks, or via
Red
Blue
the modular port using four conductor modular cable. When using
modular cable, the cable connectors MUST NOT be crimped in
reverse, as with standard telephone cable. (For a Dry Contacts WirLocation of key
Black
ing Diagram, see page 4.)
operated on-off
switch if furnished
2 Set the slide switch to the lower position. Press and hold the DOWN
Blue
Red
button on the switch to move the viewing surface to the desired
lower limit. If the screen moves in the opposite direction, release the To 110-120V Line
Single gang box by others
Black
DOWN button and press and hold down the STOP button for four
Min. 4" x 2 1/8" x 1 7/8" deep.
seconds. This will reverse the operation of the UP and DOWN
3 shown. More or less equally
switches.
feasible.
Location of key
3 Move slider switch into center position.Wait a couple of seconds.
operated on-off
Please Note: If you move the slider switch from down to up in one
switch if furnished
motion it sets the two limits in the same position.
4 Set the slide switch to the higher position. Move the viewing surface to
To 110-120V Line
desired upper limit by pressing and holding the UP button on wall switch.
5 Return the slide switch to the center position to return to normal
operation.
Wiring Diagrams—110-120V Motor and Quiet Motor
6 To set the viewing surface to an alternate format position, move the
with Built-in Low Voltage Controller
viewing surface to the desired position and press the STOP button.
Press and hold the STOP button for at least three seconds to record
Single Low Voltage Control
Multiple Low Voltage Controls
the position.
To Motor
Internal Screen Wiring
Internal Screen Wiring
with
Please Note: Pressing and releasing the UP button on the switch
White (Neutral)
White (Neutral)
UD
C +the Built-In
will move the screen to its upper limit. Pressing
and releasing
p o
o 5V Low Voltage
Black
Black
DOWN button will move the screen to its lower
w limit.
m DC
Green/Yellow (Ground)
Green/Yellow (Ground)
n
While the motor is in motion, pressing the
STOP buttonmofor less than
n
two seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the
viewing surface to its alternate format position. P O T S
Dashed wiring
by electrician
Pressing and holding the STOP button, when the motor is at rest or
Dashed wiring
Data Cable
by
electrician
in motion, for at least three seconds will record a new alternate format
Data
position.
RJ-9
Cables
connector
To Motor
To Motor
Please
Note:
5V
DC
must
be
with
Slide
with
connected to be able
to set
Built-In
Switch
UD
Wall Switch,
RJ-9
C + Built-In
Low switch.
Voltage
limits using the wall
p o
o 5V Low Voltage Back View
DC
connectors
RF or IR
w
m
n
m
o
n
P OT S
Slide
Switch
Back View
POSITION
FUNCTION
POSITION
DOWN
Receiver,
or integrated
control system
FUNCTION
Set LOWER limit
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
UP
Set UPPER limit
To 110-120V Line
CENTER
Normal Operation
*These wiring diagrams are for Access screens with motor on audience left
(standard), and fabric unrolling from the back of the roller (standard).
To Motor
with
Built-In
Low Voltage
www.draperinc.com
(765) 987-7999
To 110-120V Line