Download DAC700 - Satcom Resources Web Log

Transcript
AG
Aggregate Encoder-Decoder Ancillary Data Rate
Use this command to set or read the encoder-decoder ancillary data rate.
Syntax
AG <baud>,<parity>,<data_bits>,<stop_bits>
AG ?
Parameters
Valid <parameters> and their values are as follows:
<baud>
1200, 2400, 4800, 9600, 38400
<parity>
O, E, N (odd, even, none)
data_bits
8
<stop_bits>
2
Defaults
38400,N,8,2
Additional Information
The AG parameter data and stop bits must be set to 8 and 2, respectively.
AM
Alarm Mask
Use this command to set or read the alarm relay mask.
Syntax
AM <parameter>
AM ?
Parameters
<parameter> is the decimal number that represents the bit map of the faults to
be monitored by the status relay as shown below:
Fault Number
Fault Condition
Decimal Weight
1
Tx PLL not locked
1
2
Rx PLL not locked
2
3
Decoder not framed (out of sync)
4
4
Audio overload, left channel
8
5
Audio overload, right channel
16
6
Network or channel ID fault
32
The default is 255.
Remote Monitor and Control Operation
4-5