FRS Card ACS-FRS Card User Screens and Settings Table 2-4. FRS Circuits Screen Actions Action Function Refresh New dEl Redraws the screen. Creates new circuit. Deletes the highlighted circuit. You will be prompted with a yes/no question prior to actual deletion of the circuits. Pages up through the circuits. Pages down through the circuits. Brings up circuit performance data for the highlighted circuit. See the Circuit Performance Data section of this chapter. Shows circuit status, as described above. Used for manually switching from primary endpoint A to alternate endpoint A, and back. Used for manually switching from primary endpoint B to alternate endpoint B, and back. Returns to the FRS Card Main Screen. If changes are made to settings and not saved, you will be prompted to save or lose changes. pgUp pgDn Perf Status swA swB Main End Points NY Prm LA Prm Frame Relay Network HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S BRI HSU 530/35 60 S FXO 8139 CPU CLOCK NVRAM WAN IF T1+DS1 P 1 P 1 N HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S HSU-T 530/35 60 S BRI HSU 530/35 60 S FXO 8139 CPU CLOCK NVRAM WAN IF T1+DS1 P 1 P 1 N O D ons, E T 2 T 5A 250V IEC D ons, E Inc. ® Communicati IMACS/600 Premisys Model P Fuse 5A SB C O M T 5A 250V P IEC Fuse 5A SB LR 77063 P P 3 1 C R G R + - O + M + - VA VB VN 5A UL ® 9K09 LISTED 24/48V Source 2 Power Class P P 3 1 R G R + - O + M + - VA VB VN W1-1 ® P LR 77063 C 2 C O M Inc. Communicati IMACS/600 Premisys Model P E R M O T E R M W1-1 ~ 250V UL/CSA For CAUTION: against continued fire, same the protection with only of fuse replace rating and type 120-200-240V Hz / 60 3A, 50 NY Alt 5A UL ® 9K09 LISTED 24/48V Source 2 Power Class Telephone CSU Equipment W1-2 P 4 ~ 250V UL/CSA For CAUTION: against continued 120-200-240V Hz / 60 3A, 50 fire, same the protection with only of fuse replace rating and type LA Alt Telephone CSU Equipment DSX W1-2 P 4 DSX IAD #1 IAD #2 Router Figure 2-5.Typical FRS Endpoint Circuit STATE The State setting shows the status of the circuit. The options are stdby and actv. This setting shows the administrative state of the circuit. The operational state of each of the endpoints of the circuit is shown in the STATUS column. ENDP A Endpoint A is the FRS port used to provide service to the primary end of the PVC. All of the endpoint names assigned on the PVC Endpoints Screen (discussed earlier) are eligible options. Server Cards 2-13