Download Zhone Technologies 600 Network Card User Manual

Transcript
FRS Card
ACS-FRS Card User Screens and Settings
Table 2-4. FRS Circuits Screen Actions
Action
Function
Refresh
New
dEl
Redraws the screen.
Creates new circuit.
Deletes the highlighted circuit. You will be prompted with a yes/no question
prior to actual deletion of the circuits.
Pages up through the circuits.
Pages down through the circuits.
Brings up circuit performance data for the highlighted circuit. See the
Circuit Performance Data section of this chapter.
Shows circuit status, as described above.
Used for manually switching from primary endpoint A to alternate endpoint
A, and back.
Used for manually switching from primary endpoint B to alternate endpoint
B, and back.
Returns to the FRS Card Main Screen. If changes are made to settings and
not saved, you will be prompted to save or lose changes.
pgUp
pgDn
Perf
Status
swA
swB
Main
End Points
NY Prm
LA Prm
Frame Relay
Network
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
BRI
HSU
530/35
60
S
FXO
8139
CPU
CLOCK
NVRAM
WAN
IF
T1+DS1
P
1
P
1
N
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
HSU-T
530/35
60
S
BRI
HSU
530/35
60
S
FXO
8139
CPU
CLOCK
NVRAM
WAN
IF
T1+DS1
P
1
P
1
N
O
D
ons,
E
T
2
T 5A
250V
IEC
D
ons,
E
Inc.
®
Communicati
IMACS/600
Premisys
Model
P
Fuse
5A SB
C
O
M
T 5A
250V
P
IEC
Fuse
5A SB
LR 77063
P
P
3
1
C
R
G
R
+ - O
+ M
+ - VA VB
VN
5A
UL
®
9K09
LISTED
24/48V
Source
2 Power
Class
P
P
3
1
R
G
R
+ - O
+ M
+ - VA VB
VN
W1-1
®
P
LR 77063
C
2
C
O
M
Inc.
Communicati
IMACS/600
Premisys
Model
P
E
R
M
O
T
E
R
M
W1-1
~
250V
UL/CSA
For
CAUTION:
against
continued
fire,
same
the
protection with
only
of fuse
replace
rating
and
type
120-200-240V
Hz
/ 60
3A, 50
NY Alt
5A
UL
®
9K09
LISTED
24/48V
Source
2 Power
Class
Telephone
CSU
Equipment
W1-2
P
4
~
250V
UL/CSA
For
CAUTION:
against
continued
120-200-240V
Hz
/ 60
3A, 50
fire,
same
the
protection with
only
of fuse
replace
rating
and
type
LA Alt
Telephone
CSU
Equipment
DSX
W1-2
P
4
DSX
IAD #1
IAD #2
Router
Figure 2-5.Typical FRS Endpoint Circuit
STATE
The State setting shows the status of the circuit. The options are stdby and actv. This setting
shows the administrative state of the circuit. The operational state of each of the endpoints of
the circuit is shown in the STATUS column.
ENDP A
Endpoint A is the FRS port used to provide service to the primary end of the PVC. All of the
endpoint names assigned on the PVC Endpoints Screen (discussed earlier) are eligible
options.
Server Cards
2-13