OC335--1.qxp 05.8.5 5:05 PM Page 1 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS August 2005 No. OC335 SERVICE MANUAL Indoor unit [Model names] [Service Ref.] PLA-RP35AA.UK PLA-RP50AA.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP100AA.UK PLA-RP125AA.UK PLA-RP140AA.UK PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA PLA-RP100AA PLA-RP125AA PLA-RP140AA NOTE: • This manual describes only service data of the indoor units. PLH-P35AAH.UK PLH-P50AAH.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P100AAH.UK PLH-P125AAH.UK PLH-P140AAH.UK PLH-P35AAH PLH-P50AAH PLH-P60AAH PLH-P71AAH PLH-P100AAH PLH-P125AAH PLH-P140AAH CONTENTS 1. REFERENCE MANUAL ······································2 2. SAFETY PRECAUTION···································2 3. PART NAMES AND FUNCTIONS ···················6 4. SPECIFICATIONS ············································9 5. NOISE CRITERION CURVES ························14 6. OUTLINES AND DIMENSIONS ·····················16 7. WIRING DIAGRAM············································17 8. REFRIGERANT SYSTEM DIAGRAM ··················18 9. TROUBLESHOOTING ···································19 10. DISASSEMBLY PROCEDURE ······················35 11. PARTS LIST ···················································38 Model name indication INDOOR UNIT ON/OFF TEMP TEMP. WIRELESS REMOTE CONTROLLER ON/OFF WIRED REMOTE CONTROLLER OC335--1.qxp 1 05.8.5 5:05 PM Page 2 REFERENCE MANUAL 1-1. OUTDOOR UNIT’S SERVICE MANUAL Service Manual No. Service Ref. PUHZ-RP35/50/60/71/100/125/140VHA PUHZ-RP100/125/140YHA PUHZ-RP200/250YHA OC334 PU(H)-P·VGAA.UK PU(H)-P·YGAA.UK SUZ-KA·VA.TH OC336 MXZ-8A140VA MXZ-8A140VA1 OC316 OC338 OC322 1-2. TECHNICAL DATA BOOK Manual No. Series (Outdoor unit) PUHZ-RP·VHA(-A) PUHZ-RP·YHA(-A) PU(H)-P·VGAA.UK PU(H)-P·YGAA.UK 2 OCS01 OCS02 SAFETY PRECAUTION CAUTIONS RELATED TO NEW REFRIGERANT Cautions for units utilising refrigerant R407C Do not use the existing refrigerant piping. Use liquid refrigerant to charge the system. The old refrigerant and lubricant in the existing piping contains a large amount of chlorine which may cause the lubricant deterioration of the new unit. If gas refrigerant is used to seal the system, the composition of the refrigerant in the cylinder will change and performance may drop. Use “low residual oil piping” Do not use a refrigerant other than R407C. If there is a large amount of residual oil (hydraulic oil, etc.) inside the piping and joints, deterioration of the lubricant will result. If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may cause the lubricant deterioration. Store the piping to be used during installation indoors with keep both ends sealed until just before brazing. (Store elbows and other joints in a plastic bag.) If dust, dirt, or water enters the refrigerant cycle, deterioration of the oil and compressor trouble may result. Use a vacuum pump with a reverse flow check valve. The vacuum pump oil may flow back into the refrigerant cycle and cause the lubricant deterioration. Ventilate the room if refrigerant leaks during operation. If refrigerant comes into contact with a flame, poisonous gases will be released. Use ESTER , ETHER or HAB as the lubricant to coat flares and flange connection parts. If large amount of mineral oil enter, that can cause deterioration of refrigerant oil etc. 2 OC335--1.qxp 05.8.5 5:05 PM Page 3 [1] Cautions for service ·After recovering the all refrigerant in the unit, proceed to working. ·Do not release refrigerant in the air. ·After completing the repair service, recharge the cycle with the specified amount of liquid refrigerant. [2] Refrigerant recharging (1) Refrigerant recharging process 1Direct charging from the cylinder. ·R407C cylinder are available on the market has a syphon pipe. ·Leave the syphon pipe cylinder standing and recharge it. (By liquid refrigerant) Unit Gravimeter (2) Recharge in refrigerant leakage case ·After recovering the all refrigerant in the unit, proceed to working. ·Do not release the refrigerant in the air. ·After completing the repair service, recharge the cycle with the specified amount of liquid refrigerant. [3] Service tools Use the below service tools as exclusive tools for R407C refrigerant. No. 1 Tool name Specifications Gauge manifold ·Only for R407C. ·Use the existing fitting SPECIFICATIONS. (UNF7/16) ·Use high-tension side pressure of 3.43MPa·G or over. 2 Charge hose ·Only for R407C. ·Use pressure performance of 5.10MPa·G or over. 3 Electronic scale 4 Gas leak detector ·Use the detector for R134a or R407C. 5 Adapter for reverse flow check. ·Attach on vacuum pump. 6 Refrigerant charge base. 7 Refrigerant cylinder. ·For R407C ·Top of cylinder (Brown) ·Cylinder with syphon 8 Refrigerant recovery equipment. 3 OC335--1.qxp 05.8.5 5:05 PM Page 4 CAUTIONS RELATED TO NEW REFRIGERANT Cautions for units utilising refrigerant R410A Use new refrigerant pipes. Do not use refrigerant other than R410A. In case of using the existing pipes for R22, be careful with the followings. · For RP100, 125 and 140, be sure to perform replacement operation before test run. · Change flare nut to the one provided with this product. Use a newly flared pipe. · Avoid using thin pipes. If other refrigerant (R22 etc.) is used, chlorine in refrigerant can cause deterioration of refrigerant oil etc. Make sure that the inside and outside of refrigerant piping is clean and it has no contamination such as sulfur hazardous for use, oxides, dirt, shaving particles, etc. In addition, use pipes with specified thickness. Use a vacuum pump with a reverse flow check valve. Vacuum pump oil may flow back into refrigerant cycle and that can cause deterioration of refrigerant oil etc. Use the following tools specifically designed for use with R410A refrigerant. The following tools are necessary to use R410A refrigerant. Gauge manifold Charge hose Gas leak detector Torque wrench Contamination inside refrigerant piping can cause deterioration of refrigerant oil etc. Tools for R410A Flare tool Size adjustment gauge Vacuum pump adaptor Electronic refrigerant charging scale Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before brazing. (Leave elbow joints, etc. in their packaging.) Keep the tools with care. If dirt, dust or moisture enter into refrigerant cycle, that can cause deterioration of refrigerant oil or malfunction of compressor. If dirt, dust or moisture enter into refrigerant cycle, that can cause deterioration of refrigerant oil or malfunction of compressor. Use ester oil, ether oil or alkylbenzene oil (small amount) as the refrigerant oil applied to flares and flange connections. If large amount of mineral oil enter, that can cause deterioration of refrigerant oil etc. Charge refrigerant from liquid phase of gas cylinder. Do not use a charging cylinder. If a charging cylinder is used, the composition of refrigerant will change and the efficiency will be lowered. Ventilate the room if refrigerant leaks during operation. If refrigerant comes into contact with a flame, poisonous gases will be released. If the refrigerant is charged from gas phase, composition change may occur in refrigerant and the efficiency will be lowered. [1] Cautions for service (1) Perform service after collecting the refrigerant left in unit completely. (2) Do not release refrigerant in the air. (3) After completing service, charge the cycle with specified amount of refrigerant. (4) When performing service, install a filter drier simultaneously. Be sure to use a filter drier for new refrigerant. [2] Additional refrigerant charge When charging directly from cylinder · Check that cylinder for R410A on the market is syphon type. · Charging should be performed with the cylinder of syphon stood vertically. (Refrigerant is charged from liquid phase.) 4 OC335--1.qxp 05.8.5 5:05 PM Page 5 Unit Gravimeter [3] Service tools Use the below service tools as exclusive tools for R410A refrigerant. No. 1 Specifications Gauge manifold ·Only for R410A ·Use the existing fitting specifications. (UNF1/2) ·Use high-tension side pressure of 5.3MPa·G or over. 2 Charge hose ·Only for R410A ·Use pressure performance of 5.09MPa·G or over. 3 Electronic scale 4 Gas leak detector ·Use the detector for R134a, R407C or R410A. 5 Adaptor for reverse flow check ·Attach on vacuum pump. 6 Refrigerant charge base 7 Refrigerant cylinder ·Only for R410A Top of cylinder (Pink) Cylinder with syphon 8 Refrigerant recovery equipment 5 OC335--1.qxp 3 05.8.5 5:05 PM Page 6 PART NAMES AND FUNCTIONS ● Indoor Unit Filter Removes dust and pollutants from intake air Horizontal Air Outlet Sets airflow of horizontal automatically during cooling or dehumidifying. Grille Auto Air Swing Vane Disperses airflow up and down and adjusts the angle of airflow direction. Air Intake Intakes air from room. ● Wired remote controller On the controls are set, the same operation mode can be repeated by simply pressing the ON/OFF button. ● Operation buttons ON/OFF button Set Temperature buttons Down Fan Speed button Up Timer Menu button (Monitor/Set button) Filter button (<Enter> button) Mode button (Return button) TEMP. ON/OFF Set Time buttons Check button (Clear button) Back Ahead Test Run button MENU BACK MONITOR/SET ON/OFF FILTER DAY CHECK TEST Airflow Up/Down button Timer On/Off button (Set Day button) PAR-21MAA OPERATION CLOCK CLEAR Louver button Operation button) ( To preceding operation number. Opening the door. Ventilation button Operation button) ( To next operation number. 6 OC335--1.qxp 05.8.5 5:05 PM Page 7 ● Display “Sensor” indication Displayed when the remote controller sensor is used. Day-of-Week For purposes of this explanation, all parts of the display are shown as lit. During actual operation, only the relevant items will be lit. Shows the current day of the week. Time/Timer Display “Locked” indicator Shows the current time, unless the simple or Auto Off timer is set. If the simple or Auto Off timer is set, shows the time remaining. Indicates that remote controller buttons have been locked. Identifies the current operation “Clean The Filter” indicator Shows the operating mode, etc. * Multilanguage display is supported. Comes on when it is time to clean the filter. TIME SUN MON TUE WED THU FRI SAT TIMER Hr ON AFTER FUNCTION FILTER ˚F˚C “Centrally Controlled” indicator Indicates that operation of the remote controller has been prohibited by a master controller. Timer indicators AFTER OFF ERROR CODE ˚F˚C The indicator comes on if the corresponding timer is set. WEEKLY SIMPLE AUTO OFF ONLY1Hr. Fan Speed indicator Shows the selected fan speed. “Timer Is Off” indicator Indicates that the timer is off. Temperature Setting Shows the target temperature. Up/Down Air Direction indicator Room Temperature display Shows the room temperature. The indicator shows the direction of the outcoming airflow. Louver display “One Hour Only” indicator Indicates the action of the swing louver. Does not appear if the louver is stationary. Displayed if the airflow is set to weak and downward during COOL or DRY mode. (Operation varies according to model.) The indicator goes off after one hour, at which time the airflow direction also changes. Ventilation indicator Appears when the unit is running in Ventilation mode. (Power On indicator) Indicates that the power is on. Caution ● Only the Power on indicator lights when the unit is stopped and power supplied to the unit. ● If you press a button for a feature that is not installed at the indoor unit, the remote controller will display the “Not Available” message. If you are using the remote controller to drive multiple indoor units, this message will appear only if he feature is not present at the parent unit. ● When power is turned ON for the first time, it is normal that “PLEASE WAIT” is displayed on the room temperature indication (For max. 2minutes). Please wait until this “PLEASE WAIT” indication disappear then start the operation. 7 OC335--1.qxp 05.8.5 5:05 PM Page 8 ● Wireless remote controller CHECK TEST RUN display CHECK&TEST RUN display indicates that the unit is being checked or test-run. MODEL SELECT display Blinks when model is selected. display Lights up while transmission to the indoor unit is mode using switches. display SET TEMP. display indicates desired temperature set. CLOCK display display Displays the current time. OPERATION MODE display Operation mode display indicates which operation mode is in effect. TIMER display CHECK TEST RUN MODEL SELECT ˚C AMPM Displays when in timer operation or when setting timer. “ AMPM NOT AVAILABLE display The vertical direction of air flow is indicated. ON/OFF “ TEMP ”“ ” display Displays the order of timer operation. ”“ ” display Displays whether timer is on or off. display button FAN SPEED display indicates which fan speed has been selected. FAN AUTO STOP VANE AUTO START SET TEMPERATURE button sets any desired room temperature. ON/OFF button The unit is turned ON and OFF alternately each time the button is pressed. MODE CHECK LOUVER h FAN SPEED SELECT button Used to change the fan speed. MODE SELECT button TEST RUN SET min RESET TIMER CONTROL buttons AUTO STOP (OFF timer): when this switch is set, the air conditioner will be automatically stopped at the preset time. AUTO START (ON timer): when this switch is set, the air conditioner will be automatically started at the preset time. CLOCK Used to switch the operation mode between cooling, drying, blowing, heating and auto mode. h and min buttons Buttons used to set the “hour and minute” of the current time and timer settings. w In case the outdoor unit is cool only type, the heating mode is not available. LOUVER button CHECK-TEST RUN button This switch the horizontal fan motion ON and OFF. Only press this button to perform an inspection check or test operation. Do not use it for normal operation. (Not available for this model.) CLOCK button VANE CONTROL button RESET button Used to change the air flow direction. SET button 8 OC335--1.qxp 05.8.5 5:05 PM INDOOR UNIT Service Ref. Mode Power supply(phase, cycle, voltage) Input kW Running current A Starting current A External finish (Panel) Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT SPECIFICATIONS Service Ref. Mode Power supply(phase, cycle, voltage) Input kW Running current A Starting current A External finish (Panel) Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT 4 Page 9 Service Ref. Mode Power supply(phase, cycle, voltage) kW Input A Running current A Starting current External finish (Panel) Heat exchanger Fan Fan(drive) o No. kW Fan motor output Airflow(Low-Medium2-Medium1-High) K/min(CFM) Pa(mmAq) External static pressure kW Booster heater Operation control & Thermostat dB Noise level(Low-Medium2-Medium1-High) mm(in.) Unit drain pipe I.D. mm(in.) W Dimensions mm(in.) D mm(in.) H kg(lbs) Weight PLA-RP35AA.UK Heating Cooling Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16 0.79 1.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 11-12-13-14(390-425-460-495) 0(direct blow) – Remote controller & built-in 27-28-29-31 32 (1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 24 (53) PANEL: 5 (11) PLA-RP50AA.UK Cooling Heating Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16 0.79 1.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 14-15-16-18(495-530-565-635) 0(direct blow) – Remote controller & built-in 28-29-31-33 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 24 (53) PANEL: 5 (11) PLA-RP60AA.UK Cooling Heating Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16 0.79 1.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 14-15-16-18(495-530-565-635) 0(direct blow) – Remote controller & built-in 28-29-31-33 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 24 (53) PANEL: 5 (11) 9 INDOOR UNIT Page 10 . Service Ref Mode Power supply(phase, cycle, voltage) Input kW Running current A Starting current A External finish (Panel) Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT 05.8.5 5:05 PM Service Ref. Mode Power supply(phase, cycle, voltage) Input kW Running current A Starting current A External finish (Panel) Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT OC335--1.qxp Service Ref. Mode Power supply(phase, cycle, voltage) Input kW Running current A Starting current A External finish (Panel) Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) PLA-RP71AA.UK Cooling Heating Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16 0.79 1.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 15-16-18-20(530-565-635-705) 0(direct blow) – Remote controller & built-in 28-30-32-34 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 24 (53) PANEL: 5 (11) PLA-RP100AA.UK Cooling Heating Single phase, 50Hz, 230V 0.25 1.25 2.0 0.25 1.25 2.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.120 20-23-26-28(705-810-920-980) 0(direct blow) – Remote controller & built-in 33-36-39-41 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 30 (66) PANEL : 5 (11) PLA-RP125AA.UK Cooling Heating Single phase, 50Hz, 230V 0.33 1.64 2.0 0.33 1.64 2.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.120 22-25-28-30(775-880-990-1,060) 0(direct blow) – Remote controller & built-in 37-40-43-45 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 32 (71) PANEL : 5 (11) 10 INDOOR UNIT Page 11 Service Ref. Mode Power supply(phase, cycle, voltage) Input kW Running current A Starting current A External finish (Panel) Heat exchanger Fan Fan(drive) x No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT 05.8.5 5:06 PM Service Ref. Mode Power supply(phase, cycle, voltage) Input w1 kW Running current w1 A Starting current w1 A External finish Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater w1 kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT OC335--1.qxp Service Ref. Mode Power supply(phase, cycle, voltage) kW Input w1 A Running current w1 A Starting current w1 External finish Heat exchanger Fan Fan(drive) o No. kW Fan motor output Airflow(Low-Medium2-Medium1-High) K/min(CFM) Pa(mmAq) External static pressure kW Booster heater w1 Operation control & Thermostat dB Noise level(Low-Medium2-Medium1-High) mm(in.) Unit drain pipe I.D. mm(in.) W Dimensions mm(in.) D mm(in.) H kg(lbs) Weight PLA-RP140AA.UK Cooling Heating Single phase, 50Hz, 230V 0.33 1.64 2.0 0.33 1.64 2.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.120 22-25-28-30(775-880-990-1,060) 0(direct blow) – Remote controller & built-in 37-40-43-45 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 32 (71) PANEL : 5 (11) PLH-P35AAH.UK Cooling Heating Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16<1.29> 0.75<5.61> 1.0<5.61> Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 11-12-13-14(390-425-460-495) 0(direct blow) <1.29> Remote controller & built-in 27-28-29-31 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 26 (57) PANEL: 5 (11) PLH-P50AAH.UK Cooling Heating Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16<1.29> 0.75<5.61> 1.0<5.61> Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 14-15-16-18(495-530-565-635) 0(direct blow) <1.29> Remote controller & built-in 27-28-29-31 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 26 (57) PANEL: 5 (11) w1 : < > Shows the only booster heater rating. 11 INDOOR UNIT Page 12 Service Ref. Mode Power supply(phase, cycle, voltage) Input w1 kW Running current w1 A Starting current w1 A External finish Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater w1 kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT 05.8.5 5:06 PM Service Ref. Mode Power supply(phase, cycle, voltage) Input w1 kW Running current w1 A Starting current w1 A External finish Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater w1 kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT OC335--1.qxp Service Ref. Mode Power supply(phase, cycle, voltage) kW Input w1 A Running current w1 A Starting current w1 External finish Heat exchanger Fan Fan(drive) o No. kW Fan motor output Airflow(Low-Medium2-Medium1-High) K/min(CFM) Pa(mmAq) External static pressure kW Booster heater w1 Operation control & Thermostat dB Noise level(Low-Medium2-Medium1-High) mm(in.) Unit drain pipe I.D. mm(in.) W Dimensions mm(in.) D mm(in.) H kg(lbs) Weight PLH-P60AAH.UK Heating Cooling Single phase, 50Hz, 230V 0.16<1.93> 0.79<8.39> 1.0<8.39> 0.16 0.79 1.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 14-15-16-18(495-530-565-635) 0(direct blow) <1.93> Remote controller & built-in 28-29-31-33 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 26 (57) PANEL: 5 (11) PLH-P71AAH.UK Cooling Heating Single phase, 50Hz, 230V 0.16 0.79 1.0 0.16<1.93> 0.79<8.39> 1.0<8.39> Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 15-16-18-20(530-565-635-705) 0(direct blow) – Remote controller & built-in 28-30-32-34 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 258 (10-3/16) PANEL : 30 (1-3/16) UNIT : 26 (57) PANEL: 5 (11) PLH-P100AAH.UK Cooling Heating Single phase, 50Hz, 230V 0.25 1.25 2.0 0.25<2.39> 1.25<10.39> 2.0<10.39> Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.120 20-23-26-28(705-810-920-980) 0(direct blow) <2.39> Remote controller & built-in 33-36-39-41 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 32 (71) PANEL : 5 (11) w1 : < > Shows the only booster heater rating. 12 Page 13 INDOOR UNIT 05.8.5 5:06 PM Service Ref. Mode Power supply(phase, cycle, voltage) Input w1 kW Running current w1 A Starting current w1 A External finish Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater w1 kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) INDOOR UNIT OC335--1.qxp Service Ref. Mode Power supply(phase, cycle, voltage) Input w1 kW Running current w1 A Starting current w1 A External finish Heat exchanger Fan Fan(drive) o No. Fan motor output kW Airflow(Low-Medium2-Medium1-High) K/min(CFM) External static pressure Pa(mmAq) Booster heater w1 kW Operation control & Thermostat Noise level(Low-Medium2-Medium1-High) dB Unit drain pipe I.D. mm(in.) Dimensions mm(in.) W mm(in.) D mm(in.) H Weight kg(lbs) PLH-P125AAH.UK Heating Cooling Single phase, 50Hz, 230V 0.33<2.76> 1.64<12.00> 2.0<12.00> 0.33 1.64 2.0 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.120 22-25-28-30(775-880-990-1,060) 0(direct blow) <2.76> Remote controller & built-in 37-40-43-45 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 34 (75) PANEL : 5 (11) PLH-P140AAH.UK Heating Cooling Single phase, 50Hz, 230V 0.33 1.64 2.0 0.33<2.76> 1.64<12.00> 2.0<12.00> Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.120 22-25-28-30(775-880-990-1,060) 0(direct blow) <2.76> Remote controller & built-in 37-40-43-45 32(1-1/4) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 34 (75) PANEL : 5 (11) 13 OC335--1.qxp 5 05.8.5 5:06 PM Page 14 NOISE CRITERION CURVES PLA-RP35AA.UK PLH-P35AAH.UK NOTCH SPL(dB) High 31 Medium1 29 Medium2 28 Low 27 LINE PLA-RP50AA.UK PLA-RP60AA.UK PLH-P50AAH.UK PLH-P60AAH.UK 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 10 250 500 1000 2000 4000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE PLA-RP71AA.UK PLH-P71AAH.UK 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz NOTCH SPL(dB) High 34 Medium1 32 Medium2 30 Low 28 LINE PLA-RP100AA.UK PLH-P100AAH.UK 90 NOTCH SPL(dB) High 41 Medium1 39 Medium2 36 Low 33 LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 125 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 10 63 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) NC-20 10 8000 BAND CENTER FREQUENCIES, Hz 20 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 NOTCH SPL(dB) High 33 Medium1 31 Medium2 29 Low 28 250 500 1000 2000 4000 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 BAND CENTER FREQUENCIES, Hz 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 14 4000 8000 OC335--1.qxp 05.8.5 5:06 PM Page 15 PLA-RP125AA.UK PLH-P125AAH.UK NOTCH SPL(dB) 45 High 43 Medium1 40 Medium2 37 Low PLA-RP140AA.UK PLH-P140AAH.UK LINE 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 NOTCH SPL(dB) 45 High 43 Medium1 40 Medium2 37 Low APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 63 125 250 BAND CENTER FREQUENCIES, Hz 500 1000 2000 BAND CENTER FREQUENCIES, Hz UNIT CEILING 1.5m MICROPHONE 15 4000 8000 OC335--1.qxp Page 16 OUTLINES AND DIMENSIONS Unit : mm PLA-RP50AA.UK PLA-RP125AA.UK PLH-P50AAH.UK PLH-P125AAH.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP140AA.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P140AAH.UK Ceiling hole 860 - 910 20 - 45 20 - 45 810 Suspension bolt pitch Fresh air intake 159 16 197 {125 Burring hole pitch 120 _ 158 20 - 45 3 - {2.8 Burring hole 120_ 159 C 89 Detail drawing of fresh air intake 98 192 {150 159 840 {100 (Cut out hole) Suspension bolt M10 or W3/8 1 Ceiling surface Feeding hole (Drain pump) 286 374 60 860 - 910 Ceiling hole Terminal block 840 14 - {2.8 Burring hole Suspension bolt pitch 605 Branch duct hole 350 {175 167 155 159 130 70_ 100 90 100 100 90 Branch duct hole (Cut out hole) 20 - 45 INDOOR UNIT PLA-RP35AA.UK PLA-RP100AA.UK PLH-P35AAH.UK PLH-P100AAH.UK Drain pipe VP-25connection (O.D.{32) Power line entry Control wire entry Ceiling surface +5 0 B 135 Suspension bolt lower edge 17 +50 30 190 105 140 50 - 70 170 A 2 High efficiency filter & Fresh air intake casement (option) 577 Air intake hole Air intake grille 17 Grille Drain hole M A M Emergency operation switch (cooling) Emergency operation switch (heating) Auto vane 577 Air intake hole (WIRELESS PANEL) 411 Air outlet hole A 950 6 05.8.5 5:06 PM DEFROST/STAND BY lamp M Receiver 77 Operation lamp M Vane motor 51 411 Air outlet hole 950 77 51 Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size 1 LIQUID SIDE 2 GAS SIDE RP35, 50 RP60 RP71 [6.35 [6.35 — — — — [9.52 [9.52 [9.52 [9.52 [9.52 [9.52 [12.7 — — — — — [15.88 [15.88 [15.88 [15.88 [15.88 — — — — [19.05 — [19.05 RP100, 125, 140 P35,50,60,71 P100, 125, 140 Models A B C 258 80 298 84 PLA-RP35,50,60,71AA PLH-P35,50,60,71AAH 241 PLA-RP100,125,140AA Factory flare nut attachment to the heat-exchanger. 16 PLH-P100,125,140AAH 281 Branch duct hole OC335--1.qxp 05.8.5 5:06 PM 7 Page 17 WIRING DIAGRAM PLA-RP35AA.UK PLA-RP100AA.UK PLH-P35AAH.UK PLH-P100AAH.UK PLA-RP50AA.UK PLA-RP125AA.UK PLH-P50AAH.UK PLH-P125AAH.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP140AA.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P140AAH.UK [LEGEND] SYMBOL P.B I.B FUSE ZNR BCR CN2L CN32 CN41 CN51 LED1 LED2 LED3 X1 X4 SW1 SW2 SWE C NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE(T6.3AL250V) VARISTOR FAN CONTROL ELEMENT CONNECTOR(LOSSNAY) CONNECTOR(REMOTE SWITCH) CONNECTOR(HA TERMINAL-A) CONNECTOR(CENTRALLY CONTROL) POWER SUPPLY(I.B) POWER SUPPLY(I.B) TRANSMISSION(INDOOR-OUTDOOR) RELAY(DRAIN PUMP) RELAY(FAN MOTOR) SWITCH(MODEL SELECTION)wSee table 1 SWITCH(CAPACITY CORD)wSee table 2 CONNECTOR(EMERGENCY OPERATION) CAPACITOR(FAN MOTOR) SYMBOL MF MV H2 DP DS TB2 TB4 TB5, TB6 TH1 TH2 TH5 R.B NAME SYMBOL FAN MOTOR W.B VANE MOTOR RU DEW PREVENTION HEATER BZ DRAIN-UP MACHINE LED1 DRAIN SENSOR LED2 TERMINAL BLOCK (HEATER)wPLH-P.AAH SW1 models only or option for PLA-RP.AA models. SW2 TERMINAL BLOCK (INDOOR/ HEATER OUTDOOR CONNECTING LINE) FS1 FS2 TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE) H1 26H ROOM TEMP.THERMISTOR (0:/15k",25:/5.4k" DETECT) 88H PIPE TEMP.THERMISTOR/LIQUID (0:/15k",25:/5.4k" DETECT) COND./EVA. TEMP. THERMISTOR (0:/15k",25:/5.4k" DETECT) WIRED REMOTE CONTROLLER BOARD NAME WIRELESS REMOTE CONTROLLER BOARD RECEIVING UNIT BUZZER LED(RUN INDICATOR) LED(HOT ADJUST) SWITCH(HEATING ON/OFF) SWITCH(COOLING ON/OFF) THERMAL FUSE(72:, 16A) THERMAL FUSE(104:, 16A) HEATER HEATER THERMAL SWITCH HEATER CONTACTOR GRILLE MV MV MV MV 5 5 5 5 H2 5 MF 3 2 1 DC 13.1V 2 1 1 2 3 6 7 4 8 9 5 10 1 2 3 CNSK P.B (RED) CN2S (WHT) TB4 YLW S1 ORN S2 ORN S3 BRN TO OUTDOOR UNIT 5 1 2 3 DP BCR X4 X1 BRN ORN BLK WHT 1 3 VANE CND POWER INDOOR/OUTDOOR CN6V (ORN) CN2D COMMUNICATION (GRN) (WHT) CN3C (BLU) CN51 CN41 CN2L 1 3 POWER 1 2 FUSE D.U.M 1 3 D.HEATER 1 3 1 3 CNC(RED) CNP POWER (BLU) CNDK (RED) X4 FAN 1 3 5 (WHT) YLW ORN RED WHT YLW YLW I.B YLW YLW RED WHT BLK C X1 ZNR CN32 SWE SW2 LED3 LED2 HEATER D.SENSOR CN24 CN31 (YLW) (WHT) SW1 ON OFF DS Refer to tables 1 and 2. BLU BLU 1 2 3 LED1 INTAKE LIQUID PIPE REMOCON CN20 CN21 CN29 CN22 WIRELESS (RED) (WHT) (BLK) (BLU) CN90 1 2 1 2 1 2 1 2 (WHT) TH1 2 1 W.B BZ 9 LED1 SW1 SW2 RU R.B TB5 TRANSMISSION WIRES DC12V TH2 LED2 CNB 1 2 TB6 TB2 RED BLU GRN/YLW W1 (Fig.1) TH3 [PLH-P.AAH models only] I.B FS2 1 3 WHT 26H 88H GRY 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) 1 2 YLW YLW I.B YLW TB4S1 ORN S2 ORN S3 BRN H1 YLW ORN POWER SUPPLY ~(1PHASE) 230V 50Hz TB2 88H FS1 L RED RED RED 1 N BLU WHT 2 GRN/YLW HEATER CN24 (YLW) 6 5 WHT L N POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT Please set the voltage using the remote controller. For the setting method. please refer to the indoor unit Installation Manual. Table 1 NOTES: 1.Symbols used in wiring diagram above are, : Connector, : Terminal (block). 2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3). 3.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 4.This dlagram shows the wiring of Indoor and Outdoor connecting wires (specification of 230V), adopting superimposed system of power and signal. w1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1. w2 ; For power supply system of this unit, refer to the caution label located near this diagram. MODELS PLA-RP. AA PLH-P. AAH 1 2 3 4 5 1 2 3 4 5 ON OFF ON OFF Table 2 MODELS 17 SW1 Manufacture/Service SW2 Manufacture/Service MODELS PLA-RP35AA PLH-P35AAH 1 2 3 4 5 PLA-RP50AA PLH-P50AAH 1 2 3 4 5 PLA-RP60AA PLH-P60AAH 1 2 3 4 5 PLA-RP71AA PLH-P71AAH 1 2 3 4 5 Manufacture/Service ON OFF PLA-RP100AA PLH-P100AAH 1 2 3 4 5 ON OFF PLA-RP125AA PLH-P125AAH 1 2 3 4 5 ON OFF PLA-RP140AA PLH-P140AAH 1 2 3 4 5 ON OFF ON OFF ON OFF ON OFF OC335--1.qxp 8 05.8.5 5:06 PM Page 18 REFRIGERANT SYSTEM DIAGRAM PLA-RP35AA.UK PLA-RP100AA.UK PLH-P35AAH.UK PLH-P100AAH.UK PLA-RP50AA.UK PLA-RP125AA.UK PLH-P50AAH.UK PLH-P125AAH.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP140AA.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P140AAH.UK Strainer (#50) Heat exchanger Refrigerant GAS pipe connection (Flare) Thermistor TH5 (Cond./ Eva.temperature) Refrigerant flow in cooling Refrigerant flow in heating Refrigerant LIQUID pipe connection (Flare) Thermistor TH1 (Room temperature) Thermistor TH2 Pipe temperature(Liquid) Distributor with strainer (#50) Strainer (#50) 18 OC335--1.qxp 05.8.5 5:06 PM 9 Page 19 TROUBLESHOOTING 9-1. TROUBLESHOOTING <Error code display by self-diagnosis and actions to be taken for service (summary)> Present and past error codes are logged and displayed on the wired remote controller or controller board of outdoor unit. Actions to be taken for service and the inferior phenomenon reoccurrence at field are summarized in the table below. Check the contents below before investigating details. Unit conditions at service Error code Actions to be taken for service (summary) Displayed Judge what is wrong and take a corrective action according to “SELF-DIAGNOSIS ACTION TABLE” (9-3). Not displayed Identify the cause of the inferior phenomenon and take a corrective action according to “TROUBLESHOOTING BY INFERIOR PHENOMENA ” (9-4). The inferior phenomenon is reoccurring. 1Consider the temporary defects such as the work of protection devices in the refrigerant circuit including compressor, poor connection of wiring, noise and etc. Re-check the symptom, and check the installation environment, refrigerant amount, weather when the inferior phenomenon occurred, and wiring related. 2Reset error code logs and restart the unit after finishing service. 3There is no abnormality in electrical components, controller boards, and remote controller. Logged The inferior phenomenon is not reoccurring. 1Recheck the abnormal symptom. 2Identify the cause of the inferior phenomenon and take a corrective action according to “TROUBLESHOOTING BY INFERIOR PHENOMENA ” (9-4). 3Continue to operate unit for the time being if the cause is not ascertained. 4There is no abnormality in electrical components, controller boards, remote controller etc. Not logged 19 OC335--1.qxp 05.8.5 5:06 PM Page 20 9-2. MALFUNCTION-DIAGNOSIS METHOD BY REMOTE CONTROLLER <In case of trouble during operation> When a malfunction occurs to air conditioner, both indoor unit and outdoor unit will stop and operation lamp blinks to inform unusual stop. <Malfunction-diagnosis method at maintenance service> [Procedure] 1. Press the CHECK button twice. • "CHECK" lights, and refrigerant address "00" flashes. • Check that the remote controller's display has stopped before continuing. 2. Press the temperature buttons. • Select the refrigerant address of the indoor unit for the self-diagnosis. Note: Set refrigerant address using the outdoor unit’s DIP switch (SW1). (For more information, see the outdoor unit installation manual.) Refrigerant address display CHECK CHECK display Temperature button TEMP ON/OFF ON/OFF button MODE FAN AUTO STOP VANE AUTO START CHECK LOUVER CHECK button min TEST RUN SET h RESET CLOCK HOUR button 3. Point the remote controller at the • If an air conditioner error occurs, the sensor on the indoor unit and indoor unit's sensor emits an intermitpress the HOUR button. tent buzzer sound, the operation light flashes, and the error code is output. (It takes 3 seconds at most for error code to appear.) 4. Point the remote controller at the • The check mode is cancelled. sensor on the indoor unit and press the ON/OFF button. To be continued to the next page. 20 OC335--1.qxp 05.8.5 5:06 PM Page 21 • Refer to the following tables for details on the check codes. [Output pattern A] Beeper sounds OPERATION INDICATOR lamp flash pattern Beep Beep Beep Beep Off Beep 1st 2 nd 3 rd nth On On On On Beep Beep 1st Off On 2 nd · · · Repeated On 0.5 sec. Approx. 2.5 sec. 0.5 sec. 0.5 sec. Self-check Approx. 2.5 sec. 0.5 sec. 0.5 sec. 0.5 sec. starts (Start signal Number of flashes/beeps in pattern indicates the check Number of flashes/beeps in pattern indicates received) code in the following table (i.e., n=5 for “P5”) the check code in the following table [Output pattern B] Beeper sounds OPERATION INDICATOR lamp flash pattern Beep Beep Beep Beep 1st Off On Approx. 3 sec. Self-check Approx. 2.5 sec. starts (Start signal received) 2nd 3 rd On On On 0.5 sec. 0.5 sec. 0.5 sec. Beep Beep nth 1st On Off 0.5 sec. Approx. 2.5 sec. Number of flashes/beeps in pattern indicates the check code in the following table (i.e., n=5 for “U2”) On Approx. 3 sec. Beep 2 nd · · · Repeated On On 0.5 sec. 0.5 sec. Number of flashes/beeps in pattern indicates the check code in the following table [Output pattern A] Errors detected by indoor unit Wireless remote controller Wired remote controller Beeper sounds/OPERATION INDICATOR lamp flashes 1 Check code (Number of times) 1 P1 P2 2 P9 3 E6,E7 4 P4 P5 5 PA 6 P6 7 EE 8 P8 9 E4, E5 – 10 – 11 12 Fb E0, E3 – – E1, E2 Symptom Remark Intake sensor error Pipe (TH2) sensor error Pipe (TH5) sensor error Indoor/outdoor unit communication error Drain sensor error Drain pump error Forced compressor stop Freeing/Overheating safeguard operation Communication error between indoor and outdoor units Pipe temperature error Remote controller signal receiving error – – Indoor unit control system error (memory error, etc.) Remote controller transmission error Remote controller control board error [Output pattern B] Errors detected by unit other than indoor unit (outdoor unit, etc.) Wireless remote controller Wired remote controller Beeper sounds/OPERATION INDICATOR lamp flashes 1 Check code (Number of times) 1 E9 2 3 4 UP U3,U4 UF 5 U2 6 U1,Ud 7 8 9 10 U5 U8 U6 U7 11 U9,UH Symptom Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) Compressor overcurrent interruption Open/short of outdoor unit thermistors Compressor overcurrent interruption (When compressor locked) Abnormal high discharging temperature/49C worked/ insufficient refrigerant Abnormal high pressure (63H worked)/Overheating safeguard operation Abnormal temperature of heat sink Outdoor unit fan safeguard stop Compressor overcurrent interruption/Abnormal of power module Abnormality of super heat due to low discharge temperature Abnormality such as overvoltage or voltage shortage and abnormal synchronous signal to main circuit/Current sensor error – – Other errors (Refer to the technical manual for the outdoor unit.) Remark For details, check the LED display of the outdoor controller board. As for outdoor unit, refer to outdoor unit's service manual. – 12 – 13 Others 14 *1 If the beeper does not sound again after the initial two beeps to confirm the self-check start signal was received and the OPERATION INDICATOR lamp does not come on, there are no error records. *2 If the beeper sounds three times continuously “beep, beep, beep (0.4 + 0.4 + 0.4 sec.)” after the initial two beeps to confirm the self-check start signal was received, the specified refrigerant address is incorrect. 21 OC335--1.qxp 05.8.5 5:06 PM Page 22 • On wireless remote controller 2The continuous buzzer sounds from receiving section of indoor unit. 3Blink of operation lamp • On wired remote controller 1Check code displayed in the LCD. • If the unit cannot be operated properly after the above test run has been performed, refer to the following table to remove the cause. Symptom Cause Wired remote controller LED 1, 2 (PCB in outdoor unit) For about 2 After LED 1, 2 are lighted, LED 2 is •For about 2 minutes following power-on,opPLEASE WAIT minutes follow- turned off, then only LED 1 is eration of the remote controller is not possible lighted. (Correct operation) ing power-on due to system start-up. (Correct operation) •Connector for the outdoor unit’s protection Only LED 1 is lighted. → device is not con-nected. PLEASE WAIT → Error code LED 1, 2 blink. •Reverse or open phase wiring for the outdoor After about 2 unit’s power terminal block (L1, L2, L3) minutes has expired followDisplay messages do not •Incorrect wiring between indoor and outdoor ing power-on Only LED 1 is lighted. → appear even when operation LED 1 blinks twice, units (incorrect polarity of S1, S2, S3) switch is turned ON (operation LED 2 blinks once. •Remote controller wire short lamp does not light up). On the wireless remote controller with condition above, following phenomena takes place. • No signals from the remote controller are accepted. • OPE lamp is blinking. • The buzzer makes a short piping sound. Note: Operation is not possible for about 30 seconds after cancellation of function selection. (Correct operation) For description of each LED (LED1, 2, 3) provided on the indoor controller, refer to the following table. LED1 (power for microcomputer) LED2 (power for remote controller) Indicates whether control power is supplied. Make sure that this LED is always lit. Indicates whether power is supplied to the remote controller. This LED lights only in the case of the indoor unit which is connected to the outdoor unit refrigerant address “0”. LED3 (communication between indoor and outdoor units) Indicates state of communication between the indoor and outdoor units. Make sure that this LED is always blinking. 22 OC335--1.qxp 05.8.5 5:06 PM Page 23 Note: Refer to the manual of outdoor unit for the details of display such as F, U, and other E. 9-3. SELF-DIAGNOSIS ACTION TABLE Error Code Meaning of error code and detection method Abnormality of room temperature thermistor (TH1) 1 The unit is in three-minute resume prevention mode if short/open of thermistor is detected. Abnormal if the unit does not reset normally after three minutes. (The unit returns to normal operation, if it has normally reset.) 2 Constantly detected during cooling, drying, and heating operation. Short: 90: or more P1 Open: -40: or less Cause 1 Defective thermistor characteristics. 2 Contact failure of connector (CN20) on the indoor controller board. (Insert failure) 3 Breaking of wire or contact failure of thermistor wiring. 4 Defective indoor controller board. Countermeasure 1–3 Check resistance value of thermistor. 0: ······15.0k" 10: ····9.6k" 20: ····6.3k" 30: ····4.3k" 40: ····3.0k" If you put force on (draw or bend) the lead wire with measuring resistance value of thermistor breaking of wire or contact failure can be detected. 2 Check contact failure of connector (CN20) on the indoor controller board. Refer to 9-7. Turn the power on again and check restart after inserting connector again. 4 Check room temperature display on remote controller. Replace indoor controller board if there is abnormal difference with actual room temperature. Turn the power off, and on again to operate after check. P2 Abnormality of pipe temperature thermistor/Liquid (TH2) 1 The unit is in three-minute resume prevention mode if short/open of thermistor is detected. Abnormal if the unit does not reset normally after three minutes. (The unit returns to normal operation, if it has normally reset.) 2 Constantly detected during cooling, drying, and heating (except defrosting) operation. Short: 90: or more Open: -40: or less 1 Defective thermistor characteristics. 2 Contact failure of connector (CN21) on the indoor controller board. (Insert failure) 3 Breaking of wire or contact failure of thermistor wiring. 4 Defective refrigerant circuit is causing thermistor temperature of 90: or more or -40: or less. 5 Defective indoor controller board. 1–3 Check resistance value of thermistor. For characteristics, refer to (P1) above. 2 Check contact failure of connector (CN21) on the indoor controller board. Refer to 9-7. Turn the power on and check restart after inserting connector again. 4 Check pipe <liquid> temperature with remote controller in test run mode. If pipe <liquid> temperature is exclusively low (in cooling mode) or high (in heating mode), refrigerant circuit may have defective. 5 Check pipe <liquid> temperature with remote controller in test run mode. If there is exclusive difference with actual pipe <liquid> temperature, replace indoor controller board. Turn the power off, and on again to operate after check. P4 P5 Abnormality of drain sensor (DS) 1 Suspensive abnormality, if short/open of thermistor is detected for 30 seconds continuously. Turn off compressor and indoor fan. 2 Short/open is detected for 30 seconds continuously during suspensive abnormality. (The unit returns to normal operation, if it has normally reset.) 3 Detect the following condition. • During cooling and drying operation. • In case that pipe <liquid> temperature - room temperature <-10deg (Except defrosting) • When pipe <liquid> temperature or room temperature is short/open temperature. • During drain pomp operation. 1 Defective thermistor characteristics 2 Contact failure of connector (CN31) on the indoor controller board. (Insert failure). 3 Breaking of wire or contact failure of drain sensor wiring. 4 Defective indoor controller board. Malfunction of drain pump (DP) 1 Suspensive abnormality, if thermistor of drain sensor is let heat itself and temperature rises slightly. Turn off compressor and indoor fan. 2 Drain pomp is abnormal if the condition above is detected during suspensive abnormality. 3 Constantly detected during drain pomp operation. 1 Malfunction of drain pump 2 Defective drain Clogged drain pump Clogged drain pipe 3 Attached drop of water at the drain sensor • Drops of drain trickles from lead wire. • Clogged filter is causing wave of drain. 4 Defective indoor controller board. 1–3 Check resistance value of thermistor. 0: ······6.0k" 10: ····3.9k" 20: ····2.6k" 30: ····1.8k" 40: ····1.3k" 2 Check contact failure of connector (CN31) on the indoor controller board. Refer to 9-7. Turn the power on again and check restart after inserting connector again. 4 Replace indoor controller board if drain pump operates with the line of drain sensor connector CN31-1 and 2 is short-circuited, and abnormality reappears. Turn the power off, and on again to operate after check. 23 1 Check if drain-up machine works. 2 Check drain function. 3 Check the setting of lead wire of drain sensor and check clogs of the filter. 4 Replace indoor controller board if drain pump operates with the line of drain sensor connector CN31-1 and 2 is short-circuited and abnormality reappears. Refer to 9-7. Turn the power off, and on again to operate after check. OC335--1.qxp 05.8.5 5:06 PM Page 24 Error Code Meaning of error code and detection method Freezing/overheating protection is working 1 Freezing protection (Cooling mode) The unit is in six-minute resume prevention mode if pipe <liquid or condenser/evaporator> temperature stays under -15: for three minutes, three minutes after the compressor started. Abnormal if it stays under -15: for three minutes again within 16 minutes after six-minute resume prevention mode. <Frost prevention mode> If pipe <liquid or condenser-evaporator> temperature is 2: or below when 16 minutes has passed after compressor starts operating, unit will start operating in frost prevention mode which stops compressor operation. After that, when pipe <liquid or condenser/evaporator> temperature stays 10: or more for 3 minutes, frost prevention mode will be released and compressor will restart its operation. 2 Overheating protection (Heating mode) P6 The units is in six-minute resume prevention mode if pipe <condenser / evaporator> temperature is detected as over 70: after the compressor started. Abnormal if the temperature of over 70: is detected again within 10 minutes after six-minute resume prevention mode. (Cooling or drying mode) 1 Clogged filter (reduced airflow) 2 Short cycle of air path 3 Low-load (low temperature) operation beyond the tolerance range 4 Defective indoor fan motor • Fan motor is defective. • Indoor controller board is defective. 5 Defective outdoor fan control 6 Overcharge of refrigerant 7 Defective refrigerant circuit (clogs) (Heating mode) 1 Clogged filter (reduced airflow) 2 Short cycle of air path 3 Over-load (high temperature) operation beyond the tolerance range 4 Defective indoor fan motor • Fan motor is defective. • Indoor controller board is defective. 5 Defective outdoor fan control 6 Overcharge of refrigerant 7 Defective refrigerant circuit (clogs) 8 Bypass circuit of outdoor unit is defective. Abnormality of pipe temperature <Cooling mode> Detected as abnormal when the pipe temperature is not in the cooling range 3 minutes later of compressor start and 6 minutes later of the liquid or condenser/evaporator pipe is out of cooling range. Note 1) It takes at least 9 min. to detect. Note 2) Abnormality P8 is not detected in drying mode. Cooling range : -3 deg ] (TH-TH1) TH: Lower temperature between: liquid pipe temperature (TH2) and condenser/evaporator temperature (TH5) TH1: Intake temperature P8 <Heating mode> When 10 seconds have passed after the compressor starts operation and the hot adjustment mode has finished, the unit is detected as abnormal when condenser/evaporator pipe temperature is not in heating range within 20 minutes. Countermeasure Cause 1 Slight temperature difference between indoor room temperature and pipe <liquid or condenser / evaporator> temperature thermistor • Shortage of refrigerant • Disconnected holder of pipe <liquid or condenser / evaporator> thermistor • Defective refrigerant circuit 2 Converse connection of extension pipe (on plural units connection) 3 Converse wiring of indoor/ outdoor unit connecting wire (on plural units connection) 4 Defective detection of indoor room temperature and pipe <condenser / evaporator> temperature thermistor 5 Stop valve is not opened completely. Note 3) It takes at least 27 minutes to detect abnormality. Note 4) It excludes the period of defrosting (Detection restarts when defrosting mode is over) Heating range : 3 deg [ (TH5-TH1) 24 (Cooling or drying mode) 1 Check clogs of the filter. 2 Remove shields. 4 Measure the resistance of fan motor's winding. Measure the output voltage of fan's connector (FAN) on the indoor controller board. WThe indoor controller board should be normal when voltage of AC 220~240V is detected while fan motor is connected. Refer to 9-7. 5 Check outdoor fan motor. 67 Check operating condition of refrigerant circuit. (Heating mode) 1 Check clogs of the filter. 2 Remove shields. 4 Measure the resistance of fan motor's winding. Measure the output voltage of fan's connector (FAN) on the indoor controller board. WThe indoor controller board should be normal when voltage of AC 220~240V is detected while fan motor is connected. Refer to 9-7. 5 Check outdoor fan motor. 6~8Check operating condition of refrigerant circuit. 1~4 Check pipe <liquid or condenser / evaporator> temperature with room temperature display on remote controller and outdoor controller circuit board. Pipe <liquid or condenser / evaporator> temperature display is indicated by setting SW2 of outdoor controller circuit board as follows. Conduct temperature check with outdoor controller circuit board after connecting ‘A-Control Service Tool(PAC-SK52ST)’. ( ) 23Check converse connection of extension pipe or converse wiring of indoor/outdoor unit connecting wire. OC335--1.qxp 05.8.5 5:06 PM Page 25 Error Code Meaning of error code and detection method Abnormality of pipe temperature thermistor / Condenser-Evaporator (TH5) 1 The unit is in three-minute resume protection mode if short/open of thermistor is detected. Abnormal if the unit does not get back to normal within three minutes. (The unit returns to normal operation, if it has normally reset.) 2 Constantly detected during cooling, drying, and heating operation (except defrosting) Short: 90: or more Open: -40: or less P9 Countermeasure Cause 1 Defective thermistor 1–3 Check resistance value of thermistor. For characteristics, refer to (P1) above. characteristics 2 Check contact failure of connector (CN29) 2 Contact failure of connector on the indoor controller board. (CN29) on the indoor controller Refer to 9-7. board. (Insert failure) Turn the power on and check restart after 3 Breaking of wire or contact inserting connector again. failure of thermistor wiring. 4 Operate in test run mode and check pipe 4 Temperature of thermistor is <condenser / evaporator> temperature with 90: or more or -40: or less outdoor controller circuit board. If pipe caused by defective refrigerant <condenser / evaporator> temperature is circuit. exclusively low (in cooling mode) or high (in heating mode), refrigerant circuit may have 5 Defective indoor controller defective. board. 5 Operate in test run mode and check pipe <condenser / evaporator> temperature with outdoor control circuit board. If there is exclusive difference with actual pipe <condenser / evaporator> temperature replace indoor controller board. There is no abnormality if none of above comes within the unit. Turn the power off and on again to operate. In case of checking pipe temperature with outdoor controller circuit board, be sure to connect A-control service tool (PAC-SK52ST). ( Remote controller transmission error(E0)/signal receiving error(E4) 1 Abnormal if main or sub remote controller can not receive normally any transmission from indoor unit of refrigerant address “0” for three minutes. (Error code : E0) 2 Abnormal if sub remote controller could not receive for any signal for two minutes. (Error code: E0) E0 or E4 E3 or E5 1 Contact failure at transmission wire of remote controller 2 All remote controllers are set as “sub” remote controller. In this case, E0 is displayed on remote controller, and E4 is displayed at LED (LED1, LED2) on the outdoor controller circuit board. 3 Mis-wiring of remote controller. 4 Defective transmitting receiving 1 Abnormal if indoor controller board can circuit of remote controller not receive normally any data from 5 Defective transmitting receiving remote controller board or from other circuit of indoor controller board indoor controller board for three minutes. of refrigerant address “0”. (Error code: E4) 6 Noise has entered into the 2 Indoor controller board cannot receive transmission wire of remote any signal from remote controller for two controller. minutes. (Error code: E4) Remote controller transmission error(E3)/signal receiving error(E5) 1 Abnormal if remote controller could not find blank of transmission path for six seconds and could not transmit. (Error code: E3) 2 Remote controller receives transmitted data at the same time, compares the data, and when detecting it, judges different data to be abnormal 30 continuous times. (Error code: E3) ) 1 Check disconnection or looseness of indoor unit or transmission wire of remote controller. 2 Set one of the remote controllers “main”. If there is no problem with the action above. 3 Check wiring of remote controller. • Total wiring length: max.500m (Do not use cablex 3 or more) • The number of connecting indoor units: max.16units • The number of connecting remote controller: max.2units When it is not the above-mentioned problem of 1~3 4 Diagnose remote controllers. a) When “RC OK” is displayed, Remote controllers have no problem. Put the power off, and on again to check. If abnormality generates again, replace indoor controller board. b) When “RC NG” is displayed, Replace remote controller. c) When “RC E3” is displayed, d) When “ERC 00-06” is displayed, [ c),d)→Noise may be causing abnormality. ] ∗ If the unit is not normal after replacing indoor controller board in group control, indoor controller board of address “0” may be abnormal. 1 Set a remote controller to main, and the other to sub. 1 Two remote controller are set as “main.” (In case of 2 remote controllers) 2 Remote controller is connected 2 Remote controller is connected with only one with two indoor units or more. indoor unit. 3 Repetition of refrigerant 3 The address changes to a separate setting. address. 4 Defective transmitting receiving 4~6 Diagnose remote controller. a) When “RC OK”is displayed, remote concircuit of remote controller. 1 Abnormal if indoor controller board could trollers have no problem. 5 Defective transmitting receiving not find blank of transmission path. Put the power off,and on again to check. circuit of indoor controller (Error code: E5) When becoming abnormal again, replace board. 2 Indoor controller board receives transindoor controller board. mitted data at the same time, compares 6 Noise has entered into transb)When “RC NG”is displayed, replace the data,and when detecting it, judges mission wire of remote conremote controller. different data to be abnormal 30 troller. c)When “RC E3”or “ERC 00-66”is displayed, continuous times. (Error code: E5) noise may be causing abnormality. 25 OC335--1.qxp 05.8.5 5:06 PM Page 26 Error Code Meaning of error code and detection method Indoor/outdoor unit communication error (Signal receiving error) 1 Abnormal if indoor controller board cannot receive any signal normally for six minutes after putting the power on. 2 Abnormal if indoor controller board cannot receive any signal normally for three minutes. E6 3 Consider the unit abnormal under the following condition: When two or more indoor units are connected to one outdoor unit, indoor controller board cannot receive a signal for three minutes from outdoor controller circuit board, a signal which allows outdoor controller circuit board to transmit signals. Cause Countermeasure 1 Contact failure, short circuit or, ∗ Check LED display on the outdoor control circuit board. (Connect A-control service tool, mis-wiring (converse wiring) of PAC-SK52ST.) indoor/outdoor unit connecting Refer to EA-EC item if LED displays EA-EC. wire 1 Check disconnection or looseness of indoor/ 2 Defective transmitting receiving outdoor unit connecting wire of indoor unit or circuit of indoor controller board outdoor unit. 3 Defective transmitting receiving Check all the units in case of twin triple circuit of indoor controller board indoor unit system. 4 Noise has entered into indoor/ 2-4 Turn the power off, and on again to check. If abnormality generates again, outdoor unit connecting wire. replace indoor controller board or outdoor controller circuit board. ∗ Other indoor controller board may have defective in case of twin triple indoor unit system. E7 Indoor/outdoor unit communication 1 Defective transmitting receiving 1-3 Turn the power off, and on again to error (Transmitting error) check. If abnormality generates again, circuit of indoor controller board Abnormal if “1” receiving is detected 30 replace indoor controller board. 2 Noise has entered into power times continuously though indoor controller supply. board has transmitted “0”. 3 Noise has entered into outdoor control wire. Fb Abnormality of indoor controller board Abnormal if data cannot be normally read from the nonvolatile memory of the indoor controller board. E1 or E2 1 Defective indoor controller board. Abnormality of remote controller con1 Defective remote controller. trol board 1 Abnormal if data cannot be normally read from the nonvolatile memory of the remote controller control board. (Error code: E1) 1 Replace indoor controller board. 1 Replace remote controller. 2 Abnormal if the clock function of remote controller cannot be normally operated. (Error code: E2) PA (2502) (2500) Forced compressor stop (due to water leakage abnormality) 1 When the intake temperature subtracted with liquid pipe temperature is less than -10:, drain sensor is detected whether it is soaked in the water or not at the interval of 90 seconds. (Drain pump will start operating when the drain sensor is detected to be soaked in the water.) 2 The unit has a water leakage abnormality when the following conditions, a and b, are satisfied while the above-mentioned detection is performed. a) The drain sensor is detected to be soaked in the water 10 times in a row. b) The intake temperature subtracted with liquid pipe temperature is detected to be less than -10: for a total of 30 minutes. (When the drain sensor is detected to be NOT soaked in the water, the detection record of a and b will be cleared.) 3 The drain sensor detection is performed in operations other than cooling. (When the unit stops operating, during heating or fan operation, when the unit stops because of some abnormality) *Once the water leakage abnormality is detected, abnormality state will not be released until the main power is reset. 1) Drain pump trouble 2) Drain defective · Drain pump clogging · Drain pipe clogging 3) Open circuit of drain sensor side heater Check the drain pump. Performance Please confirm whether water can be drained. Confirm the resistance of the drain sensor side heater. 4) Contact failure of drain sensor Check the connector contact failure. connector 5) Dew condensation on drain sensor · Drain water descends along lead wire. · Drain water waving due to filter clogging. 1 Check the drain sensor leadwire mounted. 2 Check the filter clogging 6) Extension piping connection difference at twin, triple, quadruple system. Check the piping connection. 7) Mis-wiring of indoor/ outdoor connecting at twin, triple, quadruple system. Check the indoor/ outdoor connecting wires. 8) Room temperature thermistor / liquid pipe temperature thermistor detection is defective. Check the room temperature display of remote controller. Check the indoor liquid pipe temperature display of outdoor controller board. 26 OC335--1.qxp 05.8.5 5:06 PM Page 27 9-4. TROUBLESHOOTING BY INFERIOR PHENOMENA Note: Refer to the manual of outdoor unit for the detail of remote controller. Phenomena (1)LED2 on indoor controller board is off. Cause • When LED1 on indoor controller board is also off. 1 Power supply of rated voltage is not supplied to outdoor unit. 2 Defective outdoor controller circuit board. 3 Power supply of 220~240V is not supplied to indoor unit. 4 Defective indoor power board. 5 Defective indoor controller board. (For the separate indoor/outdoor unit power supply system) 1 Power supply of 220~240V AC is not supplied to indoor unit. 2 The connectors of the optional replacement kit are not used. 3 Defective indoor controller board. 4 Defective indoor power board. • When LED1 on indoor controller board is lit. 1 Mis-setting of refrigerant address for outdoor unit (There is no unit corresponding to refrigerant address “0”.) 27 Countermeasure 1 Check the voltage of outdoor power supply terminal block (L, N) or (L3, N). • When AC 220~240V is not detected. Check the power wiring to outdoor unit and the breaker. • When AC 220~240V is detected. —Check 2 (below). 2 Check the voltage between outdoor terminal block S1 and S2. • When AC 220~240V is not detected. Check the fuse on outdoor controller circuit board. Check the wiring connection. • When AC 220~240V is detected. —Check 3 (below). 3 Check the voltage between indoor terminal block S1 and S2. • When AC 220~240V is not detected. Check indoor/outdoor unit connecting wire for mis-wiring. • When AC 220~240V is detected. —Check 4 (below). 4 Check voltage output from CN2S on indoor power board (DC13.1V). Refer to 9-7-1. • When no voltage is output. Check the wiring connection. • When output voltage is between DC12.5V and DC13.7V. —Check 5 (below). 5 Check the wiring connection between indoor controller board and indoor power board. Check the fuse on indoor controller board. If no problems are found, indoor controller board is defective. 1 Check the voltage of indoor power supply terminal block (L,N). • When AC220~240V is not detected. Check the power supply wiring. • When AC220~240V is detected. -Check 2 (below). 2 Check that there is no problem in the method of connecting the connectors. • When there are problems in the method of connecting the connectors. Connect the connector correctly referring to installation manual of an optional kit. • When there is no problem in the method of connecting the connectors. -Check 3 (below). 3 Check voltage output from CNDK on indoor controller board. • When AC220~240V is not detected. Check the fuse on indoor controller board. Check the wiring connection between indoor power supply terminal block and CND on indoor controller board. • When AC220~240V is detected. -Check 4 (below). 4 Check voltage output from CN2S on indoor power board. • When no voltage output. Check the wiring connection between CNDK on indoor controller board and CNSK on indoor power board. If no problem are found,indoor power board is defective. • When DC12.5~13.7V is detected. Check the wiring connection between CN2S on indoor power board and CN2D on indoor power board. If no problem are found,indoor controller board is defective. 1 Reconfirm the setting of refrigerant address for outdoor unit Set the refrigerant address to “0”. (For grouping control system under which 2 or more outdoor units are connected, set one of the units to “0”.) Set refrigerant address using SW1 (3-6) on outdoor controller circuit board. OC335--1.qxp 05.8.5 5:06 PM Page 28 Note: Refer to the manual of outdoor unit for the detail of remote controller. Phenomena Cause Countermeasure (2)LED2 on indoor controller board is blinking. • When LED1 on indoor controller board is also blinking. Check indoor/outdoor unit connecting wire Connection failure of indoor/outdoor unit connecting for connection failure. wire • When LED1 is lit. 1 Check the connection of remote con1 Mis-wiring of remote controller wires troller wires in case of twin triple indoor Under twin triple indoor unit system, 2 or more indoor unit system. When 2 or more indoor units units are wired together. are wired in one refrigerant system, connect remote controller wires to one of those units. 2 Refrigerant address for outdoor unit is wrong or not 2 Check the setting of refrigerant address set. in case of grouping control system. Under grouping control system, there are some units If there are some units whose refrigerant whose refrigerant address is 0. addresses are 0 in one group, set one of the units to 0 using SW1 (3-6) on outdoor controller circuit board. 3 Short-cut of remote controller wires 34 Remove remote controller wires and 4 Defective remote controller check LED2 on indoor controller board. • When LED2 is blinking, check the short-cut of remote controller wires. • When LED2 is lit, connect remote controller wires again and: if LED2 is blinking, remote controller is defective; if LED2 is lit, connection failure of remote controller terminal block etc. has returned to normal. (3)Upward/downward vane performance failure 1 The vane is not downward during defrosting and heat preparation and when the thermostat is OFF in HEAT mode. (Working of COOL protection function) 2 Vane motor does not rotate. • Defective vane motor • Breaking of wire or connection failure of connector • Up/down vane setting is “No vanes”. 3 Upward/downward vane does not work. • The vane is set to fixed position. (4)Receiver for wireless remote controller 1 Weak batteries of wireless remote controller. 2 Contact failure of connector (CNB) on wireless remote controller board. (Insert failure) 3 Contact failure of connector (CN90) on indoor controller board.(Insert failure) 4 Contact failure of connector between wireless remote controller board and indoor controller board. 28 1 Normal operation (The vane is set to horizontal regardless of remote control.) 2 Check 2 (left). • Check the vane motor. (Refer to “How to check the parts”.) • Check for breaking of wire or connection failure of connector. • Check “Up/down vane setting”. (Unit function selection by remote controller). 3 Normal operation (Each connector on vane motor side is disconnected.) 1 Replace batteries of wireless remote controller. 2~4 Check contact failure of each connector. If no problems are found of connector, replace indoor controller board. When the same trouble occurs even if indoor controller board is replaced, replace wireless remote controller board. OC335--1.qxp 05.8.5 5:06 PM Page 29 9-5. EMERGENCY OPERATION 9-5-1. When wireless remote controller troubles or its battery is exhausted 1. Emergency operation is available in such a case using emergency operation switch equipped next to the receiver of indoor unit. 2. To start operation • Cooling Operation·······Press (Cooling) switch. • Heating Operation·······Press (Heating) switch. wWhen the unit starts operating, the operation lamp is lit. Emergency operation switch (cooling) Emergency operation switch (heating) Receiver Operation lamp wEmergency operation will be performed as follows. Cooling Mode Set temperature 24: Fan speed High Horizontal (30deg) Airflow direction Heating 24: High Downward (70deg) 3. To stop operation • Press either emergency operation switch (cooling/heating). 9-5-2. When wired remote controller or indoor unit micro computer troubles 1. If there is not any other wrong when trouble occurs, emergency operation starts as the indoor controller board switch (SWE) is set to ON. During the emergency operation the indoor unit is as follows; (1) Indoor fan high speed operation (2) Drain pump operation 2. When emergency operating for COOL or HEAT, setting of the switch (SWE) in the indoor controller board and outdoor unit emergency operation are necessary. 3. Check items and notices as the emergency operation (1) Emergency operation cannot be used as follows; • When the outdoor unit is something wrong. • When the indoor fan is something wrong. • When drain over flow protected operation is detected during self-diagnosis. (Error code : P5) (2) Emergency operation will be serial operation by the power supply ON/OFF. ON/OFF or temperature, etc. adjustment is not operated by the remote controller. (3) Do not operate for a long time as cold air is blown when the outdoor unit starts defrosting operation during heat emergency operation. (4) Cool emergency operation must be within 10 hours. Other wise, heat exchanger of indoor unit may get frosted. (5) After completing the emergency operation, return the switch setting, etc. in former state. (6) Since vane does not work at emergency operation, position the vane slowly by hand. 29 OC335--1.qxp 05.8.5 5:06 PM Page 30 9-6. HOW TO CHECK THE PARTS PLA-RP35AA.UK PLA-RP50AA.UK PLA-RP100AA.UK PLA-RP125AA.UK PLH-P35AAH.UK PLH-P50AAH.UK PLH-P100AAH.UK PLH-P125AAH.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP140AA.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P140AAH.UK Parts name Check points Room temperature thermistor (TH1) Pipe temperature thermistor/liquid(TH2) Condenser/Evaporator temperature thermistor (TH5) Vane motor Normal Abnormal 4.3k"~9.6k" Open or short (Refer to the thermistor) Measure the resistance between the terminals using a tester. (Surrounding temperature20:) Fan motor Normal Abnormal 15k" Open or short Measure the resistance between the terminals using a tester. (Winding temperature 20:) Relay connector 1 Disconnect the connector then measure the resistance using a tester. (Surrounding temperature 10:~30:) Red 2 White 3 Black 1 2 3 Normal Motor terminal or PLA-RP35,50,60,71AA.UK PLA-RP100,125,140AA.UK Relay connector PLH-P35,50,60,71AAH.UK PLH-P100,125,140AAH.UK Red-Black 87.2" 28.7" White-Black 104.1" 41.6" Abnormal Open or short Protector OFF:130: ON :80i20: Drain pump Measure the resistance between the terminals using a tester. (Winding temperature 20:) YLW 1 Normal Abnormal 3 290" Open or short YLW Drain sensor 1 2 3 Measure the resistance between the terminals using a tester. Measure the resistance after 3 minutes have passed since the power supply was intercepted. (Surrounding temperature 0:~60:) Normal Abnormal 0.6k"~6.0k" Open or short 30 (Refer to the thermistor) 05.8.5 5:03 PM Page 31 <Thermistor Characteristic graph> Thermistor for lower temperature Room temperature thermistor(TH1) Pipe temperature thermistor/liquid(TH2) Condenser/evaporator temperature thermistor(TH5) < Thermistor for lower temperature > 50 Resistance (K") 40 Thermistor R0=15k' ± 3% Fixed number of B=3480 ± 2% Rt=15exp { 3480( 0: 10: 20: 25: 30: 40: 1 273+t 1 )} 273 15k' 9.6k' 6.3k' 5.4k' 4.3k' 3.0k' 30 20 10 0 Thermistor for drain sensor 10 -20 -10 0 10 20 30 40 50 Temperature (:) < Thermistor for drain sensor > 9 8 Thermistor R0=6.0k' ±5% Fixed number of B=3390 ±2% 1 Rt= 6 exp { 3390( 273+t 0: 10: 20: 25: 30: 40: Resistance (K") OC335--2.qxp 1 )} 273 6.0k' 3.9k' 2.6k' 2.2k' 1.8k' 1.3k' 7 6 5 4 3 2 1 0 -20 31 0 20 40 60 Temperature (:) 80 OC335--2.qxp 05.8.5 5:03 PM Page 32 9-7.TEST POINT DIAGRAM 9-7-1. Power board PLA-RP35AA.UK PLA-RP50AA.UK PLA-RP100AA.UK PLA-RP125AA.UK PLH-P35AAH.UK PLH-P50AAH.UK PLH-P100AAH.UK PLH-P125AAH.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP140AA.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P140AAH.UK CN2S Connect to the indoor controller board (CN2D) 1 (+)) Between 1 to 3 12.6-13.7V DC (Pin1 CNSK Connect to the indoor controller board (CNDK) Between 1 to 3 220-240V AC 32 OC335--2.qxp 05.8.5 5:03 PM Page 33 9-7-2. Indoor controller board PLA-RP35AA.UK PLA-RP50AA.UK PLA-RP100AA.UK PLA-RP125AA.UK PLH-P35AAH.UK PLH-P50AAH.UK PLH-P100AAH.UK PLH-P125AAH.UK CN3C Transmission (Indoor/outdoor) (0~24V DC) CN2D Connect to the indoor power board (CN2S) (12.5~13.7V DC) PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP140AA.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P140AAH.UK LED1 Power supply (I.B) LED2 Power supply (R.B) LED3 Transmission (Indoor/outdoor) CN22 Connect to the terminal block(TB5) (Remote controller connecting wire) (10.4~14.6V DC) CN20 Room temperature thermistor (TH1) CNDK Connect to the indoor power board (CNSK) (220~240V AC) CN21 Pipe temperature thermistor/Liquid (TH2) CN29 Condenser/evaporator temperature thermistor (TH5) FUSE (6.3 A 250 V) CN31 Drain sensor (DS) CN90 Connect to the wireless remote controller board (CNB) CND Power supply input (220~240V AC) CN6V Vane motor output (MV) CNP Drain-pump output (DP) (220~240V AC) CN41 Connector (HA terminal-A) CN51 Centrally control CN24 Heater output (12V DC) SWE Emergency operation CN2L Connector (LOSSNAY) FAN Fan motor output Jumper wire J41, J42 Pair number setting with wireless remote controller 33 SW2 Capacity setting SW1 Model setting OC335--2.qxp 05.8.5 5:03 PM Page 34 9-8. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE Each function is controlled by the dip switch and the jumper wire on control p.c. board. (Marks in the table below) Jumper wire Functions SW1 Model settings Setting by the dip switch and jumper wire MODELS PLA-RP. AA PLH-P. AAH MODELS SW2 Capacity settings J41 J42 Pair number setting with wireless remote controller JP1 Unit type setting JP3 Indoor controller board type setting : Short : Open) Remarks Manufacture/Service 1 2 3 4 5 1 2 3 4 5 ON OFF ON OFF Manufacture/Service PLA-RP35AA PLH-P35AAH 1 2 3 4 5 PLA-RP50AA PLH-P50AAH 1 2 3 4 5 PLA-RP60AA PLH-P60AAH 1 2 3 4 5 PLA-RP71AA PLH-P71AAH 1 2 3 4 5 PLA-RP100AA PLH-P100AAH 1 2 3 4 5 PLA-RP125AA PLH-P125AAH 1 2 3 4 5 PLA-RP140AA PLH-P140AAH 1 2 3 4 5 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF <Settings at time of factory shipment> Wireless remote controller: 0 Control PCB: (for both J41 and J42) Four pair number settings are supported. The pair number settings of the wireless remote controller and indoor control PCB (J41/J42) are given in the table on the left. (' ' in the table indicates the jumper line is disconnected.) Wireless remote Control PCB setting controller setting J41 J42 0 1 2 3~9 Model Without TH5 With TH5 Jumper wire ( JP1 Indoor controller board type Factory shipment Service parts There is no jumper (JP1) because these models have the cond./eva. temperature thermistor (TH5). JP3 34 OC335--2.qxp 05.8.5 5:03 PM 10 Page 35 DISASSEMBLY PROCEDURE PLH-P71AAH.UK Be careful on removing heavy parts. OPERATING PROCEDURE PHOTOS & ILLUSTRATIONS 1. Removing the air intake grille (1) Slide the knob of air intake grille toward the arrow 1 to open the air intake grille. (2) Remove drop prevention hook from the panel. (3) Slide the shaft in the hinge to the direction of the arrow2 and remove the air intake grille. Figure 1 Air intake grille Grille Air intake grille knob 2. Removing the fan guard (1) Open the air intake grille. (2) Remove the 3 screws of fan guard. Photo 1 Screws Fan guard Air intake grille 3. Removing the room temperature thermistor (1)Remove the fan guard.(See photo 1) (2) Remove the screw in the room temperature thermistor holder to remove the holder and the room temperature thermistor. (3) Remove the 1 screw from the bell mouth, and unscrew the other 2 screws (fix to the oval hole which has a different diameter) to remove the bell mouth. (4) Hold the holder claw, and remove the room temperature thermistor and holder. (5) Disconnect the connector (red) from the indoor control board. Photo 2 Screws Bell mouth 4. Removing the electrical box Photo 3 (1) Remove the fan guard.(See photo 1) (2) Disconnect the lead wire of the vane motor from the clamp, and disconnect the white connector (10P). Turbo fan (3) Remove the room temperature thermistor with the holder. (4) Remove the bell mouth.(See photo 2) (5) Disconnect the relay connector in the electrical box. Red (3P) for fan motor Electrical White (2P) for pipe temperature detecting thermistor box Blue (3P) for drain pump White (3P) for drain sensor Green (6P) for auxiliary heater (6) Remove the 3 screws of the electrical box and loosen the other 2 screws to remove the box. Power <Electrical parts in the electrical box> supply Indoor controller board board Power supply board Terminal block Connector Capacitor Heater contactor 35 Room temperature thermistor Air intake grille Nut Capacitor Heater contactor Terminal block Indoor controller board Connector OC335--2.qxp 05.8.5 5:03 PM Page 36 OPERATING PROCEDURE PHOTOS & ILLUSTRATIONS 5. Remove the fan motor (1) Remove the fan guard.(See photo 1) (2) Remove the bell mouth.(See photo 2) (3) Remove the electrical box.(See photo 3) (4) Remove the turbo fan nut. (5) Pull out the turbo fan. (6) Disconnect the connector of the fan motor lead wire. (7) Remove the 4 nuts of the fan motor. Photo 4 Fan motor Nut Nuts 6. Removing the pipe temperature thermistor and condenser evaporator temperature thermistor (1) Remove the fan guard.(See photo 1) (2) Remove the bell mouth.(See photo 2) (3) Remove the electrical box.(See photo 3) (4) Remove the turbo fan. (5) Remove the screw of the service panel. (6) Remove the service panel. (7) Remove the pipe temperature thermistor which is inserted into the holder installed to the thin copper pipe. (8) Disconnect the 2-pin white connector.(CN21) [Condenser/ evaporator temperature thermistor] (9) Remove the drain pan. (See Photo 7) (10) Remove the thermistor which is installed into the holder installed to the indoor coil. (11) Disconnect the 2-pin black connector. (CN29) Photo 5 Connector Pipe temperature thermistor Service access 7. Removing the panel (1) Remove the air intake grille.(See figure 1) Corner panel (See figure 2)ß (1) Remove the corner screw. (2) Slide the corner panel to the direction of the arrow3, and remove the corner panel. Panel (See photo 6) (1) Disconnect the connector that connects with the unit. (2) Remove the 2 screws from the panel and loosen another 2 screws, which fix to the oval holes, have different diameters. (3) Rotate the panel a little to remove the panel. Figure 2 8. Removing the drain pan (1) Remove the panel. (See photo 6) (2) Remove the drain plug (Larger one), drain the remaining water in the drain pan. (3) Remove the corner cover. (2 screws) (4) Remove the bell mouth (See photo 2) (5) Remove the electrical box. (See photo 3) (6) Remove the lead wire holder. (1 screw) (7) Remove the 4 screws and pull out the drain pan. w Pull out the left and right of the pan gradually. Be careful not to crack or damage the pan. Photo 7 Corner Screw panel Panel Corner panel Photo 6 Connector Screws Panel Screws Screw Screw Drain pan Screw Screw Lead wire holder 36 Drain plug(Larger) Corner cover OC335--2.qxp 05.8.5 5:03 PM Page 37 OPERATING PROCEDURE PHOTOS & ILLUSTRATIONS 9. Removing the drain pump and drain sensor (1) Remove the panel. (See photo 6) (2) Remove the fan guard. (See photo 1) (3) Remove the bell mouth. (See photo 2) (4) Remove the electrical box. (See photo 3) (5) Remove the drain pan. (See photo 7) (6) Remove the 3 screws of the drain pump. (7) Cut the drain hose band, pull out the drain hose from the drain pump. (8) Pull out the drain pump. (9) Remove the drain sensor and the holder. Photo 8 Drain sensor Screw Fixing band Drain hose Screw Drain pump 10. Removing the heat exchanger (1) Remove the panel. (See photo 6) (2) Remove the fan guard. (See photo 1) (3) Remove the bell mouth. (See photo 2) (4) Remove the electrical box. (See photo 3) (5) Remove the drain pan. (See photo 7) (6) Remove the turbo fan. (See photo 4) (7) Remove the 3 screws of the piping cover, and pull out piping cover. (8) Remove the 4 screws of the outer wall cover, and pull out the outer wall cover. (9) Remove the screw of the coil support. (10) Remove the 2 screws of the coil. (11) Pull out the heat exchanger. Photo 9 Coil support Coil screws Heat exchanger Coil support Coil support Photo 10 Screw Outer wall cover Piping cover 11. Removing the heater (1) Remove the panel. (See photo 6) (2) Remove the electrical box. (See photo 3) (3) Remove the bell mouth.(See photo 2) (4) Remove the drain pan.(See photo 7) (5) Remove the turbo fan.(See photo 4) (6) Remove the 5 screws of the heater assembly. (7) Remove the clamp(1 screw) securing the lead wire. (8) Pull the heater assembly out. Lead wire clamp Heater assembly 37 Screws of piping cover Heater screw OC335--2.qxp 05.8.5 5:03 PM 11 Page 38 PARTS LIST PANEL PARTS PLA-RP35AA.UK PLA-RP50AA.UK PLA-RP60AA.UK PLA-RP71AA.UK PLA-RP100AA.UK PLA-RP125AA.UK PLA-RP140AA.UK PLH-P35AAH.UK PLH-P50AAH.UK PLH-P60AAH.UK PLH-P71AAH.UK PLH-P100AAH.UK PLH-P125AAH.UK PLH-P140AAH.UK GEAR 12 GEAR (VANE) 11 VANE BUSH 2 10 9 STEPPING MOTOR 3 8 1 4 5 13 7 RECEIVER 14 6 CHECK TEST RUN MODEL SELECT ˚C AMPM AMPM NOT AVAILABLE ON/OFF TEMP. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ON/OFF Parts No. S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 E10 E01 E01 E00 E00 E00 24K E00 E00 E00 E00 E01 KW1 E15 58A 15 TEMP 003 002 638 638 500 691 658 317 223 063 040 040 713 714 246 Q'ty / set Remarks Wiring RecomSpecifiPLA-RP35,50,60,71,100,125,140AA.UK Diagram mended Parts Name (Drawing cation PLH-P35,50,60,71,100,125,140AAH.UK No.) Symbol Q'ty WIRED WIRELESS 1 1 AIR OUTLET GRILLE 4 4 VANE ASSY 1 2 CORNER PANEL 3 2 CORNER PANEL 1 1 L.L FILTER-A 1 1 GRILLE ASSY 1 RECEIVER RU 1 WIRELESS ADAPTER W.B 4 4 STEPPING MOTOR MV 8 8 VANE BUSH 4 4 GEAR (VANE) 4 4 GEAR 1 REMOTE CONTROLLER ASSY PAR-21MAA-E R.B 1 WIRELESS REMOTE CONTROLLER ASSY PAR-SL97A-E CORD 1 38 Price Unit Amount OC335--2.qxp 05.8.5 5:03 PM Page 39 FUNCTIONAL PARTS PLA-RP35AA.UK PLA-RP50AA.UK PLA-RP60AA.UK PLA-RP71AA.UK 16 15 14 13 1 2 2 3 12 4 5 11 MOTOR CAP SPL WASHER 6 10 CONDENSER EVAPORATOR TEMPERATURE THERMISTOR 7 9 PIPE TEMPERATURE THERMISTOR 8 FLARE NUT Q'ty / set No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Parts No. S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 003 E01 005 E00 E00 08K K16 E17 E40 E15 17J E20 E50 E00 E02 E06 A41 006 687 130 688 130 114 097 480 480 480 097 202 202 129 659 130 762 105 688 Parts Name Specification BASE LEG DRUM 1 ASSY LEG TURBO FAN SPL WASHER / NUT HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER FLARE NUT 5/8" PIPE TEMPERATURE THERMISTOR CONDENSER EVAPORATOR TEMPERATURE THERMISTOR MOTOR CAP INNER COVER LEG FAN MOTOR D17B6P70MS MOTOR MOUNT DRUM 2 ASSY PLA-RP·AA.UK 35,50 1 2 1 1 1 1 1 39 60 1 2 1 1 1 1 71 1 2 1 1 1 1 Remarks Wiring Recom(Drawing Diagram mended Symbol Q'ty No.) 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 4 1 TH2 TH5 MF Price Unit Amount OC335--2.qxp 05.8.5 5:03 PM Page 40 FUNCTIONAL PARTS PLA-RP100AA.UK PLA-RP125AA.UK PLA-RP140AA.UK 15 14 16 13 1 2 2 3 12 4 5 11 MOTOR CAP SPL WASHER 6 10 CONDENSER EVAPORATOR TEMPERATURE THERMISTOR 7 9 PIPE TEMPERATURE THERMISTOR 8 FLARE NUT Q'ty / set No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Parts No. S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 003 E01 007 E00 E01 08K K18 K19 E16 17J E20 E50 E02 E02 E07 A41 008 687 130 688 130 114 097 480 480 097 202 202 129 659 130 762 105 688 Parts Name Specification BASE LEG DRUM 1 ASSY LEG TURBO FAN SPL WASHER HEAT EXCHANGER HEAT EXCHANGER FLARE NUT 3/4" PIPE TEMPERATURE THERMISTOR CONDENSER EVAPORATOR TEMPERATURE THERMISTOR MOTOR CAP INNER COVER LEG FAN MOTOR D176P120MS MOTOR MOUNT DRUM 2 ASSY PLA-RP.AA.UK 100 1 2 1 1 1 1 1 1 1 1 1 1 1 1 4 1 40 125,140 1 2 1 1 1 1 1 1 1 1 1 1 1 1 4 1 Remarks Wiring Recom(Drawing Diagram mended Symbol Q'ty No.) TH2 TH5 MF Price Unit Amount OC335--2.qxp 05.8.5 5:03 PM Page 41 FUNCTIONAL PARTS PLH-P35AAH.UK PLH-P50AAH.UK PLH-P60AAH.UK PLH-P71AAH.UK 20 19 18 17 1 2 2 3 16 4 5 15 MOTOR CAP 14 THERMAL FUSE SPL WASHER 6 13 THERMAL FUSE 12 HEATER THERMAL 7 SWITCH 11 10 CONDENSER EVAPORATOR TEMPERATURE THERMISTOR 8 9 PIPE TEMPERATURE THERMISTOR Q'ty / set No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Parts No. S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 003 E01 005 E00 E00 08K E08 E07 E20 17J E20 20J 46K E02 E03 E50 E01 E02 E06 A41 006 687 130 688 130 114 097 300 300 480 202 202 303 700 706 706 129 659 130 762 105 688 Parts Name BASE LEG DRUM 1 ASSY LEG TURBO FAN SPL WASHER HEATER ELEMENT HEATER ELEMENT HEAT EXCHANGER PIPE TEMPERATURE THERMISTOR CONDENSER EVAPORATOR TEMPERATURE THERMISTOR INSULATOR HEATER THERMAL SWITCH THERMAL FUSE THERMAL FUSE MOTOR CAP INNER COVER LEG FAN MOTOR MOTOR MOUNT DRUM 2 ASSY Specification 240V/467W 240V/700W 50°C OFF 104°C, 16A 72°C, 16A D17B6P70MS 41 PLH -P·AAH.UK 35,50 1 2 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 4 1 60 1 2 1 1 1 1 71 1 2 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 4 1 3 1 1 1 1 1 1 1 1 1 1 4 1 Remarks Wiring RecomDiagram mended (Drawing No.) Symbol Q'ty H1 H1 TH2 TH5 26H FS2 FS1 MF Price Unit Amount OC335--2.qxp 05.8.5 5:04 PM Page 42 FUNCTIONAL PARTS PLH-P100AAH.UK PLH-P125AAH.UK PLH-P140AAH.UK 20 19 18 17 1 2 2 3 16 4 5 15 MOTOR CAP 14 THERMAL FUSE SPL WASHER 6 13 THERMAL FUSE 12 HEATER THERMAL 7 SWITCH 11 10 CONDENSER EVAPORATOR TEMPERATURE THERMISTOR 8 9 PIPE TEMPERATURE THERMISTOR Q'ty / set No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Parts No. S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 S70 003 E01 007 E00 E01 08K E06 E05 E21 E25 17J E20 20J 46K E02 E04 E50 E04 E02 E07 A41 008 687 130 688 130 114 097 300 300 480 480 202 202 303 700 706 706 129 659 130 762 105 688 Parts Name BASE LEG DRUM 1 ASSY LEG TURBO FAN SPL WASHER HEATER ELEMENT HEATER ELEMENT HEAT EXCHANGER HEAT EXCHANGER PIPE TEMPERATURE THERMISTOR CONDENSER EVAPORATOR TEMPERATURE THERMISTOR INSULATOR HEATER THERMAL SWITCH THERMAL FUSE THERMAL FUSE MOTOR CAP INNER COVER LEG FAN MOTOR MOTOR MOUNT DRUM 2 ASSY Specification 240V/867W 240V/1000W PLH -P100 AAH.UK 1 2 1 1 1 1 3 Remarks Wiring RecomPLH -P125,140 (Drawing No.) Diagrammended Symbol Q'ty AAH.UK 1 2 1 1 1 1 H1 H1 3 1 50°C OFF 104°C, 16A 72°C, 16A D176P120MS 1 1 1 1 1 1 1 1 1 1 4 1 42 1 1 1 1 1 1 1 1 1 1 1 4 1 TH2 TH5 26H FS2 FS1 MF Price Unit Amount OC335--2.qxp 05.8.5 5:04 PM Page 43 FUNCTIONAL PARTS PLA-RP35AA.UK PLA-RP100AA.UK PLA-RP50AA.UK PLA-RP125AA.UK PLA-RP60AA.UK PLA-RP140AA.UK PLA-RP71AA.UK 1 2 17 DRAIN PLUG 16 DRAIN PLUG 3 15 4 14 CAPACITOR 5 6 13 TERMINAL BLOCK 7 12 TERMINAL BLOCK 8 11 ROOM TEMPERATURE THERMISTOR 9 10 Part numbers that is circled is not shown in the figure. Q'ty / set No. Parts No. S70 1 S70 S70 2 S70 3 S70 4 S70 5 S70 6 S70 7 S70 8 S70 9 S70 10 S70 11 S70 12 S70 13 S70 S70 14 S70 S70 15 S70 16 S70 17 S70 18 S70 E02 E00 E01 29H E02 E00 31K E30 K06 K80 003 E10 E00 512 E01 576 17T E02 001 A48 A41 A41 529 529 529 523 355 266 241 501 313 310 503 675 202 716 716 255 255 255 663 524 524 523 Parts Name DRAIN PAN DRAIN PAN DRAIN PAN DRAIN SOCKET DRAIN PUMP DRAIN SENSOR DRAIN SENSOR HOLDER ELECTRICAL CONTROL BOX POWER BOARD INDOOR CONTROLLER BOARD CONTROL COVER ASSY FAN GUARD ROOM TEMPERATURE THERMISTOR TERMINAL BLOCK TERMINAL BLOCK CAPACITOR CAPACITOR CAPACITOR CORNER COVER DRAIN PLUG DRAIN PLUG DRAIN HOSE ASSY Specification PLA-RP · AA.UK 35,50,60 1 71 1 100 125,140 Remarks Wiring RecomDiagram mended (Drawing No.) Symbol Q'ty 1 2P (1, 2) 3P (S1, S2, S3) 3+ 440V 3.5+ 440V 7+ 440V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 43 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DP DS P.B I.B TH1 TB5 TB4 C C C Price Unit Amount OC335--2.qxp 05.8.5 5:04 PM Page 44 FUNCTIONAL PARTS PLH-P35AAH.UK PLH-P100AAH.UK PLH-P50AAH.UK PLH-P125AAH.UK PLH-P60AAH.UK PLH-P140AAH.UK PLH-P71AAH.UK 1 19 DRAIN PLUG 2 18 DRAIN PLUG 3 17 4 16 CAPACITOR 5 15 RELAY 6 14 TERMINAL BLOCK 7 13 TERMINAL BLOCK 12 TERMINAL BLOCK 8 11 ROOM TEMPERATURE THERMISTOR 9 10 Part number that is circled is not shown in the figure. Q'ty / set No. Parts No. S70 1 S70 S70 2 S70 3 S70 4 S70 5 S70 6 S70 7 S70 8 S70 9 S70 10 S70 11 S70 12 S70 13 S70 14 S70 15 S70 S70 16 S70 S70 17 S70 18 S70 19 S70 20 S70 E02 E00 E01 29H E02 E00 31K E30 K06 K80 003 E10 E00 512 E01 521 71G 576 17T E02 001 A48 A41 A41 529 529 529 523 355 266 241 501 313 310 503 675 202 716 716 716 215 255 255 255 663 524 524 523 Specification Parts Name DRAIN PAN DRAIN PAN DRAIN PAN DRAIN SOCKET DRAIN PUMP DRAIN SENSOR DRAIN SENSOR HOLDER ELECTRICAL CONTROL BOX POWER BOARD INDOOR CONTROLLER BOARD CONTROL COVER ASSY FAN GUARD ROOM TEMPERATURE THERMISTOR TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK RELAY CAPACITOR CAPACITOR CAPACITOR CORNER COVER DRAIN PLUG DRAIN PLUG DRAIN HOSE ASSY PLH -P • AAH.UK 35,50,60 1 71 1 100 125,140 Remarks Wiring RecomDiagram mended (Drawing No.) Symbol Q'ty Price Unit Amount 1 2P (1, 2) 3P (S1, S2, S3) 3P (L, N, ;) JC-1A DC12V 3+ 440V 3.5+ 440V 7.0+ 440V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DP DS P.B I.B TH1 TB5 TB4 TB2 88H C C C HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN CCopyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO., LTD. Distributed in Aug. 2005 No.OC335 PDF 8 Made in Japan. New publication, effective Aug. 2005. Specifications subject to change without notice.