12.0 Fault Finding
12.1 Central Heating
Switch on power,
set selectors for
CH on and DHW
off.
Set all controls to
call for heat.
Does the burner
fire?
YES
Do radiators get
hot?
YES Is lockout lamp on
burner or panel
lit?
Does boiler cycle
on its thermostat?
NO
Is high limit
Press reset
YES
thermostat lamp
button, replace if
lit?
necessary.
NO
Check wiring,
replace boiler
thermostat.
NO
Is there continuity
across the boiler
stat connections
17 and 18 on the
PCB?
YES
Check relay and
PCB, replace.
NO
Check all valves
are open and
pump is working,
check pressure,
check all air is
vented.
YES
NO
Refer to burner
fault finding.
NO
Is there continuity
across the
connections 28
and 30 on the
PCB?
YES
YES
Check power
from clock or
switch, check
wiring fuses and
mains supply.
Page 44
HEATING IS
WORKING
NORMALLY
NO
Check boiler
thermostat,
replace if
necessary.