Maintenance Using BIT Every time the radio is turned on, a self-test procedure is performed. If an internal malfunction is found, an error message will be displayed. Please contact your service representative and report the malfunction or error indicated by the BIT function. Table 7 lists the error messages that may be generated by the BIT function. Table 7. Error Messages Error Code Meaning Probable Cause 00 O.K. – no errors 01 DSP boot checksum fail (during download) LORD board problem 02 DSP PLL unlock LORD board problem 03 DSP external RAM memory LORD board problem 04 Not applicable 05 DSP internal RAM memory 06 Not applicable 07 Not applicable 08 HC16 flash memory checksum LORD board problem 09 HC16 RAM memory LORD board problem 10 No 16.8 MHz clock Check for good power cable connection. LORD board problem Possible LORD board problem 11 Battery low Weak internal battery: replace battery to correct problem 12 Control head wake-up Control head problems 13 Control head is not responding Control head problems 14 Radio not programmed Problem experienced during programming. Program radio (connect MRC or RSS at 1200 bps) 15 Database fail ALE scanned channels do not match the programmed channels by means of the MRC or RSS 16 VCO 1 first injection LORD board problem 17 VCO 2 first injection LORD board problem 18 VCO 3 first injection LORD board problem 19 VCO second injection LORD board problem 20 Synthesizer unlock LORD board problem 21 Receiver failure LORD board problem 22 Preselector range 1 LORD board problem 23 Preselector range 2 LORD board problem 125