Parameters List of Parameters r7843[0...20] Description: Notice: Note: r7901[0...43] Description: Memory card serial number / Mem_card ser.no Access level: 4 Calculated: - Data type: Unsigned8 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - Max - Factory setting - Displays the actual serial number of the memory card. The individual characters of the serial number are displayed in the ASCII code in the indices. An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual. Example: displaying the serial number for a memory card: r7843[0] = 49 dec --> ASCII characters = "1" --> serial number, character 1 r7843[1] = 49 dec --> ASCII characters = "1" --> serial number, character 2 r7843[2] = 49 dec --> ASCII characters = "1" --> serial number, character 3 r7843[3] = 57 dec --> ASCII characters = "9" --> serial number, character 4 r7843[4] = 50 dec --> ASCII characters = "2" --> serial number, character 5 r7843[5] = 51 dec --> ASCII characters = "3" --> serial number, character 6 r7843[6] = 69 dec --> ASCII characters = "E" --> serial number, character 7 r7843[7] = 0 dec --> ASCII characters = " " --> serial number, character 8 ... r7843[19] = 0 dec --> ASCII characters = " " --> serial number, character 20 r7843[20] = 0 dec Serial number = 111923E Sampling times / t_sample Access level: 4 Calculated: - Data type: FloatingPoint32 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - [µs] Max - [µs] Factory setting - [µs] Displays the sampling times currently present on the drive unit. For r7901[x] = 0, the following applies: The time slice is not active. r7903 Description: Hardware sampling times still cannot be assigned / HW t_samp free Access level: 3 Calculated: - Data type: Unsigned16 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - Max - Factory setting - Displays the number of hardware sampling times that can still be assigned. These free sampling times can be used by OA applications such as DCC (Drive Control Chart) or FBLOCKS (free function blocks). Note: r8570[0...39] OA: Open Architecture Macro drive object / Macro DO Access level: 1 Calculated: - Data type: Unsigned32 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - Max - Factory setting - Description: Displays the macro file saved in the appropriate directory on the memory card/device memory. Dependency: Refer to: p0015 Note: For a value = 9999999, the following applies: The read operation is still running. © Siemens AG 2011 All Rights Reserved SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011 1-331
Related documents
Siemens CU230P-2 Technical data
Siemens EH.85M.21E Technical data
List Manual G120C - Service, Support
List Manual G120C
Safety Integrated - SINAMICS G110M, G120 - Service
Operating Instructions
SERVICE MANUAL FOR KH
Tratamiento de los errores
2 - Cascade Corporation
ST KT2USB - Common Criteria
MM HA16 NG GB.book
Water Softeners