Download List Manual G120C - Service, Support
Transcript
Parameters Parameter list r0948[0...63] Fault time received in milliseconds / t_fault recv ms Access level: 3 Calculated: - Data type: Unsigned32 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - [ms] Max - [ms] Factory setting - [ms] Description: Displays the system runtime in milliseconds when the fault occurred. Dependency: Refer to: r0945, r0947, r0949, r2109, r2130, r2133, r2136 Notice: The time comprises r2130 (days) and r0948 (milliseconds). Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139). The structure of the fault buffer and the assignment of the indices is shown in r0945. When the parameter is read via PROFIdrive, the TimeDifference data type applies. r0949[0...63] Fault value / Fault value Access level: 3 Calculated: - Data type: Integer32 Data set: - Can be changed: - Scaling: - Units group: - Unit selection: - Min - Max - Factory setting - Description: Displays additional information about the fault that occurred (as integer number). Dependency: Refer to: r0945, r0947, r0948, r2109, r2130, r2133, r2136 Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139). The structure of the fault buffer and the assignment of the indices is shown in r0945. p0952 Fault cases, counter / Fault cases qty Access level: 3 Calculated: - Data type: Unsigned16 Can be changed: U, T Scaling: - Data set: - Units group: - Unit selection: - Min 0 Max 65535 Factory setting 0 Description: Number of fault situations that have occurred since the last reset. Dependency: The fault buffer is deleted (cleared) by setting p0952 to 0. Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136 r0963 PROFIBUS baud rate / PB baud rate G120C_DP Access level: 3 Calculated: - Data type: Unsigned16 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min 0 Max 255 Factory setting - Description: Displays the corresponding value for the PROFIBUS baud rate. Value: 0: 1: 2: 3: 4: 6: 7: 8: 9: 10: 1-96 9.6 kbit/s 19.2 kbit/s 93.75 kbit/s 187.5 kbit/s 500 kbit/s 1.5 Mbit/s 3 Mbit/s 6 Mbit/s 12 Mbit/s 31.25 kbit/s © Siemens AG 2012 All Rights Reserved SINAMICS G120C List Manual (LH13), 01/2012, A5E03052632B AB
Related documents
List Manual G120C
SINAMICS G120C SINAMICS
ComBridge Studio Visual Editor V 1.6.6 User Manual
Display - Internet
Bunn A-10 Specifications
Diagnostics Manual - Service, Support
Manual - AudioVisual Online
5 - Advanced Test Equipment Rentals
Descarga
Conversores de frequência montados em unidade de
Siemens CU230P-2 Technical data
Siemens SINAMICS G120C