Download Simrad PI54 A Specifications
Transcript
Simrad PI54 Depth sensor, test procedure Tools and equipment required • Multimeter • A small piece of wire • PI System Initial check and setup identification Keep the area between the negative charging lug (A) and the water detector (B) clean to reduce the risk of activating the sensor. If necessary, apply silicon grease to disrupt conductive paths. 1 Using a multimeter, check the voltage between the negative charging lug (A) and the water detector (B). Make sure the sensor is charged: - Fully discharged: Voltage less than 11.5 Vdc - Fully charged: Voltage greater than 13.5 Vdc - Approximately 50% capacity left: 12.8 Vdc 2 With a small piece of wire, complete the circuit between the sensor’s sea water detector (B) and negative charging lug (A). - The sensor will respond by flashing its individual LED identification codes. (1) = One long flash: It has a duration of approximately 1 second. (2) = One start flash: This signals that the first digit of the channel number is next. (3) = None, one, two or three short flashes: The number of short flashes signifies the first digit of the configured channel number. (4) = A second start flash: This signals that the second digit of the channel number is next. 276 850-165186 / Rev.B