During the armed state (night), the internal (console) and external (if used) alarm sounders will activate and the communicator will report alarms. A system-wide programmed number of alarm reports for this zone will be allowed to be transmitted in one armed period. Restorals will be sent when the zone is restored for a time greater than its physical response time (less than 1 second). Type 6. 24–HOtJR SILENT ZONE: Sensors assigned to this zone, when faulted, will initiate a caumunicator report. There will be no local displays or alarm sounds. Upon keying the security code plus OFF, there will be a memory indication of the faulted zone. A system-wide programmed nunber of alarm reports for this zone will be allowed to be transmitted (swinger suppression) by the communicator until an OFF sequence is performed (security code plus OFF). The caumunicator will transmit a restoral message when the zone is restored for a time greater than its physical response time (less than 1 second). During the disarmed state, a faulted zone will result in a ‘~ DISARMED— Press * to show faults” display (5137) or a NOT READY display (4137). If an “off” sequence is performed (Code + OFF), followed by depression of the * key, all the descriptors and/or numbers of the faulted zones will be sequentially displayed. Faulting a zone of this type will initiate a 24-HOUR AUDIBLE ZONE: loud audible alarm externally and at the console, an LCD display, and Pressing any key will silence the a programmed canmunicator report. Keying the security code plus OFF Console sounder for 10 seconds. A system-wide programmed number will permanently silence the alarm. of alarm reports for this zone will be allowed to be transmitted (swinger suppression) by the canrnunicator until an OFF sequence is performed . The communicator will transmit a restoral message when the zone is restored for a time greater than its physical response time (less than 1 second). Type 8. 24-HOUR AUXILIARY ZONE: Faulting a zone of this type will initiate a steady alarm sound at the console, an ALARM display, and a programmed communicator report. Pressing any key will silence the Console sounder Keying the security code plus OFF will permanently for 10 seconds. A system-wide programmed number of alarm reports silence the alarm. for this zone will be allcwed to be transmitted (swinger suppression) The by the communicator until an OFF sequence is performed. canmunicator will transmit a restoral message when the zone is restored for a time greater than its physical response time (less than 1 second). Type 9. FIRE ZONE: Opens in this zone will result in ‘troubles”. Shorts will result in alarms. Note: Zone 1 will support 2-wire Smoke Detectors (using the EOL resistor configuration); Zones 2 through 8 (and 10 through 17, if used) can be used for heat detectors and pull &ations and for 4–wire Smoke Detectors with external (manual) power interrupt; Zone 9 cannot be used for Fire. A fire zone in trouble will not Fire zones may not be bypassed. prevent the burglary system frcm being armed in any mode. A system-wide programmed number of alarm reports for this zone will be allowed to be transmitted (swinger suppression) by the canmunicator in 8