Download ADEMCO Alpha Vista Console Programming instructions

Transcript
During the armed state (night), the internal (console) and external
(if used) alarm sounders will activate and the communicator will
report alarms. A system-wide programmed number of alarm reports for
this zone will be allowed to be transmitted in one armed period.
Restorals will be sent when the zone is restored for a time greater
than its physical response time (less than 1 second).
Type 6.
24–HOtJR SILENT ZONE:
Sensors assigned to this zone, when faulted,
will initiate a caumunicator report. There will be no local displays
or alarm sounds. Upon keying the security code plus OFF, there will be
a memory indication of the faulted zone.
A system-wide programmed nunber of alarm reports for this zone will be
allowed to be transmitted (swinger suppression) by the communicator
until an OFF sequence is performed (security code plus OFF). The
caumunicator will transmit a restoral message
when the zone is
restored for a time greater than its physical response time (less than
1 second).
During the disarmed state, a faulted zone will result in a ‘~
DISARMED—
Press * to show faults” display (5137) or a NOT READY display (4137).
If an “off” sequence is performed (Code + OFF), followed by depression
of the * key, all the descriptors and/or numbers of the faulted zones
will be sequentially displayed.
Faulting a zone of this type will initiate a
24-HOUR AUDIBLE ZONE:
loud audible alarm externally and at the console, an LCD display, and
Pressing any key will silence the
a programmed canmunicator report.
Keying the security code plus OFF
Console sounder for 10 seconds.
A system-wide programmed number
will permanently silence the alarm.
of alarm reports for this zone will be allowed to be transmitted
(swinger suppression) by the canrnunicator until an OFF sequence is
performed . The communicator will transmit a restoral message when the
zone is restored for a time greater than its physical response time
(less than 1 second).
Type 8.
24-HOUR AUXILIARY ZONE: Faulting a zone of this type will initiate a
steady alarm sound at the console, an ALARM display, and a programmed
communicator report. Pressing any key will silence the Console sounder
Keying the security code plus OFF will permanently
for 10 seconds.
A system-wide programmed number of alarm reports
silence the alarm.
for this zone will be allcwed to be transmitted (swinger suppression)
The
by the communicator
until an OFF sequence
is performed.
canmunicator will transmit a restoral message when the zone is
restored for a time greater than its physical response time (less than
1 second).
Type 9.
FIRE ZONE: Opens in this zone will result in ‘troubles”. Shorts will
result in alarms. Note:
Zone 1 will support 2-wire Smoke Detectors
(using the EOL resistor configuration); Zones 2 through 8 (and 10
through 17, if used) can be used for heat detectors and pull &ations
and for 4–wire Smoke Detectors with external (manual) power interrupt;
Zone 9 cannot be used for Fire.
A fire zone in trouble will not
Fire zones may not be bypassed.
prevent the burglary system frcm being armed in any mode.
A system-wide programmed number of alarm reports for this zone will be
allowed to be transmitted (swinger suppression) by the canmunicator in
8