Download DCS Compact LCD 24B User guide
Transcript
PROSTAR DCS COMPACT TECHNICAL MANUAL PROGRAMMING PART 2 DECEMBER 1994 MMC: 200 OPEN CUSTOMER PROGRAMMING DESCRIPTION: Used to open and close customer level programming. If programming is not opened and an attempt is made to access a system MMC, the error message [NOT PERMIT] will be displayed. A four digit passcode is required to access this MMC. Each digit can be 0–9. When opened, this MMC enables access to all MMCs allowed in MMC 802 Customer Access MMC Number. PROGRAM KEYS UP & DOWN KEYPAD SPK TRSF Select open or closed Used to enter passcode Save data and advance to next MMC Exit programming ACTION DISPLAY 1. Press TRSF 200 Display shows ENABLE CUS.PROG. PASSCODE: 2. Enter passcode ENABLE CUS.PROG. PASSCODE: Correct code shows ENABLE CUS.PROG. DISABLE Incorrect code shows ENABLE CUS.PROG. PASSWORD ERROR 3. Press UP or DOWN arrow key to select ENABLE or DISABLE Press RIGHT soft key OR Dial 1 for ENABLE or dial 0 for DISABLE 4. Press SPK to advance to MMC entry level and press UP or DOWN key to select MMC OR Enter MMC number and press RIGHT soft key to enter MMC ENABLE CUS.PROG. ENABLE HOME PAGE Table of Contents