Download Raining Data Corporation Raining DataCorp. mvEnterprise Installation guide

Transcript
MSG_Exception: Event Handler Messages
w3Pipe::StartConnect(): connect(), errorcode
Meaning:
Failure during socket connection under UNIX.
Severity:
FCService will fail.
Action:
Check errorcode and resolve underlying problem.
w3Pipe::StartConnect(): CreateEvent()
Meaning:
Failure to create an event during socket connection start-up under
Windows.
Severity:
FCService will fail.
Action:
Check errorcode and resolve underlying problem.
w3Pipe::StartConnect(): CreateFile(), errorcode
Meaning:
Unable to create a pipe file under Windows.
Severity:
FCService will fail.
Action:
Check errorcode and resolve underlying problem.
w3Pipe::StartRead() buf!=NULL, bufsz<1
Meaning:
Internal error trying to create a second buffer during read from pipe!
Severity:
FCService will fail.
Action:
Contact Raining Data Customer Support.
w3Pipe::StartRead() ERROR_PIPE_NOT_CONNECTED, possible
Flash/NonFlash compile mismatch", errorcode
Meaning:
For D3: It’s likely that the application has aborted. This may be due to
Flash and non-Flash compiled modules being mixed.
For mvBase: It’s likely that the application has aborted.
Severity:
Page will fail.
Action:
For D3: Ensure that all applications are Flash-compiled and running
properly.
For mvBase: Ensure that all applications are running properly.
FlashCONNECT Administrator’s Guide
193