Installation and Operating Instructions
9
MENU
STRUCTURE
To facilitate simple operation of the device, the device, operating and display functions are
combined into 4 groups (= main menu).
The four menus
• Information
• Program
• Manual operation
• Basic setting
Menu
Information
Program
provide information on your solar thermal
system.
The currently active menu is displayed by
means of the relevant graphic symbol in the
top row of the display.
Overview of functions contained
Main menu for the automatic control of the solar system.
• Display of current measured values
• Display of system status
• Display of error messages
• Display of energy yield (if existing)
Change and set the programmable setting values (parameters)
Note: Changes can impede system functions
Manual operation Switching the connected pumps/valves on and off manually
Basic setting
Information on the basic settings for the system function.
Note: Settings and changes may only be carried out by trained personnel.
9.1 “Info”
menu
In this operating mode, all measured values and operating states are displayed.
i
Only the configuration-specific symbols are displayed.
Resettable values such as minimum and maximum temperatures, daily yield and overall yield
can be reset as follows:
Select value using the
and
Reset value using the
button
Confirm “OK?” message with
SDC 306
buttons
= no or
= yes
1316BED036-11B-E
- 21 -
Date 06/09