Download Conair 7 User guide
Transcript
Structure and Function TrueBlend™ Pos 1 & 2, Main components Pos 3 & 6, Main or additive components Pos 4 & 5, Additive components 6 position Position 1 Position 2 Position 3 Position 6 Controller location Position 5 Position 4 Front door – (mix chamber) Fig.10; Layout of six component material hoppers All the following six component blenders utilize fixed hopper positions: 5.4 Model Pos 1 & 2 Pos 3 & 4 Pos 5 & 6 TB250-6 Fixed Fixed Fixed TB500-6 Fixed Fixed Fixed TB900-6 Fixed Fixed Fixed TB1800-5/6 Fixed Fixed Fixed TB2500-5/6 Fixed Fixed Fixed TB3500-5/6 Fixed Fixed Fixed Operating modes The TrueBlend operates in three different operating modes: • Gravimetric mode: all components are metered and weighed in sequence. • Volumetric mode: all components are metered in sequence without weighing. • Combined mode: a gravimetric cycle is followed by an adjustable number of volumetric cycles. 40 Edition: February 2008