TrueBlend™
4.5
Transport and Setup
Making connections
4.5.1
Compressed air connection
Î Connect the air hose [1] to the compressed air connection of the unit [2].
The operating pressure must be at least 0.6 MPa (87.0 psi) (6 bar).
Î Check the operating pressure with the manometer [3] and if it is different set it
to 0.6 MPa.
[1] Air hose
[2] Compressed air connection
[3] Manometer
Fig. 6: Connecting compressed air
NOTE
4.5.2
No additional compressed air consumers may be connected to the unit, because this may reduce the operating pressure. If the operating pressure is
less than 0.6 MPa the loading precision may be affected.
Electrical connection
Î Connect the gravimetric batch blending unit to the mains power-supply system.
Î Check that the unit functions after assembly (see 7.7 Startup).
NOTE
Electrical supply must be a clean power source with nothing else on the circuit (for example self-loading loaders.) The unit must be grounded to a lug by
the sensor on the back of the unit.
Edition: February 2008