Download Dialogic M7324 User`s guide

Transcript
1.60
Enhanced GCAMS on Dialogic® DM3 Boards
This release provides the following enhancements to the Global Call Alarm Management
System (GCAMS) for Dialogic® DM/V and DM/V-A Media Boards:
• Ability for the application to be notified of several new T1/E1 alarms, supported on
ISDN, CAS, and R2MF protocols through existing GCEV_ALARM, GCEV_BLOCKED,
and GCEV_UNBLOCKED
• Ability to change default threshold values for the new alarms through the configuration
file
• Ability for the GCAMS functions in the Dialogic® Global Call API library to recognize
the new alarms
• Default values of non-blocking and “no notify” for each new alarm with the ability to
change each value via gc_SetAlarmConfiguration( )
• Alarm reporting behavior for the new alarms is the same as the behavior on
Springware boards
Details on these enhancements are provided next.
1.60.1
New E1 Alarms
The following table lists new alarms for E1 technology. These new alarms are nonblocking and not received by default. To change these default values, use the
gc_SetAlarmConfiguration( ) function.
Table 7. New Alarms for E1 Technology (DM3 Boards)
Alarm
1.60.2
Meaning
Default
Threshold
Value
Range
DTE1_BPVS
Bipolar violation count saturation
255
0 to 255
DTE1_CECS
CRC4 error count saturation
255
0 to 255
DTE1_ECS
Frame sync bit error count saturation
0
0 to 255
New T1 Alarms
The following table lists new alarms for T1 technology. These new alarms are non-blocking
and not received by default. To change these default values, use the
gc_SetAlarmConfiguration( ) function.
Dialogic® System Release 6.0 PCI for Windows® Release Update, Rev 62 — January 30, 2008
Dialogic Corporation
233