Download Compaq AlphaServer 800 System information
Transcript
System Machine Check (SCB: 660) A system machine check is a system- or processor-detected error that occurred as a result of an “off-chip” request to the system. The following conditions cause PALcode to build the 660/670 machine check logout frame and invoke the 660 error handler. • • • • • • • • • • • CIA-detected noncorrectable ECC error CIA-detected command/address parity error CIA-detected nonexistent memory reference PCI bus parity error PCI command/address parity error PCI master abort PCI target abort Scatter/gather invalid translations table entry I/O timeout System overtemperature (event) Unexpected IPL 23 interrupt request Processor-Detected Correctable Errors (SCB: 630) Processor-detected correctable errors are generic Alpha 21164A microprocessor correctable errors. The error-handling code should be common across all platforms that use the Alpha 21164A. The following conditions cause PALcode to invoke the operating system 630 error handler: • • Single-bit I-stream ECC error Single-bit D-stream ECC error System-Detected Nonfatal Error (SCB: 620) These nonfatal errors are AlphaServer 800-specific correctable errors. The following conditions cause the PALcode to invoke the operating system 620 error handler: • • • 5-4 DMA read errors High temperature warning (event) Fan warning/failure (event)—This event is fatal and noncorrectable, though reported as nonfatal. The OS then shuts the system down. AlphaServer 800 Service Guide