Download Datalogic Magellan 9500? Specifications

Transcript
Code 39 Minimum Label Length
This feature specifies the minimum allowable length of a Code 39 label.
Length in this case includes check, data and ASCII characters, but does not
include start, or stop characters. This feature applies when Code 39 Length
Control is set to variable-length decoding.
NOTE
Minumum label length should be less than or equal to maximum label length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET CODE 39 MINIMUM LABEL LENGTH
below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for
this option is 00 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (00-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODE 39 MINIMUM LABEL LENGTH
6-200
Magellan® 9500