Download Datalogic Magellan 9500? Specifications

Transcript
I 2 of 5 Maximum Label Length
This feature specifies the maximum allowable length of an I 2 of 5 label.
Length in this case includes check and data characters, but does not include
start or stop characters. This feature applies when I 2 of 5 Length Control is
set to variable-length decoding.
NOTE
Maximum label length should be greater than or equal to minimum label
length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET I 2 OF 5 MAXIMUM LABEL LENGTH
below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for
this option is 02 to 50, even numbers only. Pad all single digit numbers with a leading zero to yield a two-digit entry (02-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET I 2 OF 5 MAXIMUM LABEL LENGTH
6-228
Magellan® 9500