Download Schaerer Celebration BC Technical data
Transcript
www.schaerer.com Installation & Commissioning Power supply Mains voltage tolerance 400 V (± 10 %) 200 – 220 V (± 10 %) mains break < 50 ms no functional interruption Protection IP 50 Model BCL Model Fuse (installation site) Connection cable conductor cross-section 3 x 16A 5 x 1.5mm2 3 x 16A 5 x 1.5mm2 1 x 30A 3 x 4mm2 3 x 16A 5 x 1.5mm2 2 x 30A 4 x 10AWG Fuse (installation site) Connection cable conductor cross-section 3 x 16A 5 x 1.5mm2 3000-3400W 1 x 16A 3 x 1.5mm2 5800-6900W 1 x 30A 3 x 4mm2 10200W 3 x 16A 5 x 1.5mm2 2 x 30A 4 x 10AWG 2 x 16A 3 x 1.5mm2 Fuse (installation site) Connection cable conductor cross-section 3000-3400W 3 x 16A 5 x 1.5mm2 5800-6900W 1 x 30A 3 x 4mm2 2 x 30A 4 x 10AWG 2 x 16A 3 x 1.5mm2 Power rating 380-415V 3N~ 50/60Hz SCC BCL Europe 220-240V ~ 50Hz SCC BCL Korea 400V 3N~ 50/60Hz SCC BCL Japan, Saudi-Arabia, Norway-Net B 200-220V 3~ 50/60Hz 8500-10100W 3000-3400W 5800-6900W 10200W 7400-8400W 5000-5700W Model BC Model Power rating 8500-10100W 380-415V 3N~ 50/60Hz SCC BC Europe 3000-3400W 5800-6900W 220-240V ~ 50Hz SCC BC Korea 400V 3N~ 50/60Hz SCC BC Japan, Saudi-Arabia, Norway-Net B 200-220V 3~ 50/60Hz 200-220V 2~ 50/60Hz 7400-8400W 5000-5700W 5000-5700W Model C Model Power rating SCC C Europe 220-240V ~ SCC C Japan, Saudi-Arabia, NorwayNet B 200-220V 3~ 50/60Hz 200-220V 2~ 50/60Hz 50Hz 7400-8400W 5000-5700W 5000-5700W The device must be electrically connected according to all valid regulations (VDE 0100) as well as national stipulations. The type of power cable must be at least H05 RN-F. The voltage specified on the serial plate must match the supply voltage at the installation location. Caution! Risk of damage to the machine! Programming manual / V01 / 02.2010 ●● The phase must be protected from short-circuits with the Ampere value mentioned on the serial plate! ●● All poles of the device must be able to be disconnected from the power supply. ●● Never operate a device with a faulty power cord. Have a defective power cord or plug replaced immediately by a qualified service technician. ●● Schaerer Ltd. advises against the use of extension cables! If an extension cable must be used, nevertheless (minimum cross-section: 1.5 mm2), please observe the cable manufacturer’s data (instructions for use) and all local regulations. ●● Power cords must be connected in such a way that no one can trip over them. Do not pull the cords over corners or sharp edges, pinch them between objects or allow them to hang loosely in a room. Do not place cables over hot objects, and protect them from oil and aggressive cleaning agents. ●● Never lift or pull the device by its power cord. Never pull the plug out of the socket by its cord. Never touch the power cord or plug with wet hands! Never insert a wet plug into a power socket! 9 / 62