Download Schaerer Celebration BC Technical data

Transcript
www.schaerer.com
Installation & Commissioning
Power supply
Mains voltage tolerance
400 V (± 10 %) 200 – 220 V (± 10 %) mains break < 50 ms no functional
interruption
Protection
IP 50
Model BCL
Model
Fuse (installation site)
Connection
cable conductor
cross-section
3 x 16A
5 x 1.5mm2
3 x 16A
5 x 1.5mm2
1 x 30A
3 x 4mm2
3 x 16A
5 x 1.5mm2
2 x 30A
4 x 10AWG
Fuse (installation site)
Connection
cable conductor
cross-section
3 x 16A
5 x 1.5mm2
3000-3400W
1 x 16A
3 x 1.5mm2
5800-6900W
1 x 30A
3 x 4mm2
10200W
3 x 16A
5 x 1.5mm2
2 x 30A
4 x 10AWG
2 x 16A
3 x 1.5mm2
Fuse (installation site)
Connection
cable conductor
cross-section
3000-3400W
3 x 16A
5 x 1.5mm2
5800-6900W
1 x 30A
3 x 4mm2
2 x 30A
4 x 10AWG
2 x 16A
3 x 1.5mm2
Power rating
380-415V 3N~
50/60Hz
SCC BCL Europe
220-240V ~
50Hz
SCC BCL Korea
400V 3N~
50/60Hz
SCC BCL Japan,
Saudi-Arabia, Norway-Net B
200-220V 3~
50/60Hz
8500-10100W
3000-3400W
5800-6900W
10200W
7400-8400W
5000-5700W
Model BC
Model
Power rating
8500-10100W
380-415V 3N~
50/60Hz
SCC BC Europe
3000-3400W
5800-6900W
220-240V ~
50Hz
SCC BC Korea
400V 3N~
50/60Hz
SCC BC Japan,
Saudi-Arabia, Norway-Net B
200-220V 3~
50/60Hz
200-220V 2~
50/60Hz
7400-8400W
5000-5700W
5000-5700W
Model C
Model
Power rating
SCC C Europe
220-240V ~
SCC C Japan, Saudi-Arabia, NorwayNet B
200-220V 3~
50/60Hz
200-220V 2~
50/60Hz
50Hz
7400-8400W
5000-5700W
5000-5700W
The device must be electrically connected according to all valid regulations (VDE 0100) as well as national stipulations. The type of power cable must be at least H05 RN-F. The voltage specified on the serial
plate must match the supply voltage at the installation location.
Caution!
Risk of damage to
the machine!
Programming manual / V01 / 02.2010
●● The phase must be protected from short-circuits with the Ampere value mentioned on the serial plate!
●● All poles of the device must be able to be disconnected from the power supply.
●● Never operate a device with a faulty power cord. Have a defective power cord or plug replaced immediately by a qualified service technician.
●● Schaerer Ltd. advises against the use of extension cables! If an extension cable must be used,
nevertheless (minimum cross-section: 1.5 mm2), please observe the cable manufacturer’s data
(instructions for use) and all local regulations.
●● Power cords must be connected in such a way that no one can trip over them. Do not pull the cords
over corners or sharp edges, pinch them between objects or allow them to hang loosely in a room.
Do not place cables over hot objects, and protect them from oil and aggressive cleaning agents.
●● Never lift or pull the device by its power cord. Never pull the plug out of the socket by its cord.
Never touch the power cord or plug with wet hands! Never insert a wet plug into a power socket!
9 / 62