Download MTD 128-255A Technical data

Transcript
SightLine Applications Command and Control
offset
2
Packet length = 11
3
Packet type = 0x71 NEW: 2.19
4
Mode (1 = freeze Auto-gain at min/max below)
5,6
Auto-gain Max value (max value maps to 255 in 8 bit output)
7,8
Auto-gain Min Value (min value maps to 0 in 8 bit output)
9
Row ROI for Auto-gain stats. Row Offset in % of image height
(255=100%)
Full image (default) = 0
10
Column ROI for Auto-gain stats. Col Offset in % of image width
(255=100%)
Full image (default) = 0
11
High ROI for Auto-gain stats. Height in % of image height (255=100%)
Full image (default) = 255
12
Wide ROI for Auto-gain stats. Width in % of image width (255=100%)
Full image (default) = 255
Set User Palette (0x72)
Set the Y, U, V values for the user false color palette.
Byte
offset
2, 3
Description
Packet length = 770. Note: extended size packet.
4
Packet type = 0x72 NEW: 2.20
5
Y value for first entry
6
U value for first entry
7
V Value for first entry
...
770
Y value for last entry
771
U value for last entry
772
V Value for last entry
Current User Palette(0x73)
Return the current user palette in YUV values.
Byte
Copyright © 2014-2015 SightLine Applications, Inc.
Description
Page 90 of 95
Jan 15, 2015