Download Comtech EF Data KP-10 Unit installation
Transcript
Errata A Comtech EFData Documentation Update Subject: Changes to Chapter 3 (Communications Link Jumper Setting) Date: Document: July 28, 1997 RSU-503 Redundancy Switch Unit Installation and Operation Manual, Rev. 8, dated April 4, 1997 MN/RSU503.EA8 Attach this page to page 3-1 Part Number: Collating Instructions: Comments: The following changes provide the correct information for jumper placement when choosing between RS-232 or -485. This information will be incorporated into the next revision. Change Specifics: 3.4.1 Communications Link The terminal functions can be remotely controlled and monitored via an RS-485 or RS-232 communications link. • The RS-485 interface makes it possible to operate 255 terminals on a common communications link. • The RS-232 interface is used to communicate with a single terminal. The M&C module must be hardware configured on the M&C board to one of the two interfaces. Refer to the following table for jumper placement at JP1: RS-485 Configuration 1-2 3-4 5-6 7-8 Filename: T_ERRATA RS-232 Configuration 9-10 11-12 13-14 15-16 1