Download EdilKamin POWER Technical data
Transcript
sk tecnica Multilingua TINY_KELLY cod 665980 _definitiva x stampa.qxp 24/06/2011 9.56 Pagina 51 ENGLISH TROUBLESHOOTING TIPS FOR TINY 5) Black Out: (not a defect of the stove). Turns off due to lack of electricity Check electricity connection and drops in voltage. 6) Fault/RC: (intervenes if the thermo coupling has failed or is disconnected). Turns off due to thermo coupling failed or disconnected Check connection of thermo coupling to board: check function in cold test. 7) smoke °C/high: turns off due to exceeding maximum smoke temperature. Excessive smoke temperature may depend on: pellet type, anomaly in smoke extraction, smoke channel blocked, incorrect installation, gear motor ‘drift’ Remote control inefficient: • closer to the receiver of the stove • check the battery and if necessary, replace it Output air not hot: • clean the hearth exchanger. During ignition, the differential switch trips (DEALER): • check moisture content of ignition resistance Does not ignite: • clean combustion chamber. “Battery check”: • The stove does not stop but the error appears on the display. • The buffer battery of the control board needs changing. NOTA 1 All signals/warnings remain shown until you intervene on the remote control, by pressing the button Do not use the insert before having eliminated the problem. NOTA 2 After 1000 kg of pellets consumed, the display flashes the wording ‘Mainten.’. The stove works, but you must call the Dealer out to perform extraordinary maintenance. 50 .