Download Creator Electronics CR-M4102 Specifications

Transcript
(2) Execution timing
The current value is changed for a designated axis at the rising edge (OFF →
ON) of the CHGA command.
Sequence program
END
END
END
END
CHGA command
executio
CHGA command
ON
Command accept
flag
ON
Start accept flag
(axis)
Current value change
Current value change processing
ON
Command start accept
completion device (D1+0)
ON: For abnormal
completion only
Device of status display
for command start
accept completed (+1)
Completion of command
acceptance at motion CPU side
1-scan
(3) Operation error conditions
An operation error occurs in the following cases and the SVST command is not
executed.
(a) When the machine (set for reservation) is designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
(b) When the local machine is designated by object machine CPU head No.
input/output No. ÷ 16 [nl]
(c) When a CPU other than Q motion CPU is designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
(d) When the command is configured of devices other than usable device
(e) When 0 to 3DFH, 3E4H and following are designated by object machine
CPU head No. input/output No. ÷ 16 [nl]
A - 33