Download Manx SA7x Specifications
Transcript
RA7x/SA7x Pocket Reference Guide 65 EB—Firmware Detected Fault - SDI Driver Error Description: The I/O processor firmware has detected an inconsistency in the SDI driver. This driver provides the interface to the controller and the read/write hardware via the SDI gate array. FN: 10—exp.idx.hsw.—expired index/sector pulse timer (head switch) FN: 11—inv.head.hsw—invalid physical head switch (head switch) FN: B0—inv.sdi.lsn.—invalid SDI logical state number FN: BA—exp.idx.tmr.—expired index/sector timer FN: BD—inv.spu.IRQ.—invalid or spurious IRQ interrupt FN: BE—inv.head.adr.—invalid physical head address FN: BF—inv.head.num.—invalid logical head number Most Probable Cause: ECM ED—Firmware Detected Fault - SDI Handler Error Description: The I/O processor firmware has detected an inconsistency in the SDI handler. This handler processes and performs SDI level 2 command packets provided by the SDI driver. In addition, it provides the SDI level 2 response packets to the SDI driver. FN: D7—inv.cpy.byct.—invalid buffer copy byte count FN: D8—inc.sub.unt.—incorrect subunit mask bit FN: DA—drv.hrd.flt.—drive hard fault—CANNOT be cleared Most Probable Cause: ECM EE—Firmware Detected Fault - Diagnostic Driver Error Description: The I/O processor firmware has detected an inconsistency in the diagnostic driver. This driver performs the drive’s power on reset diagnostics. FN: EB—inv.dsp.drv.—invalid DSP driver response Most Probable Cause: ECM