Download McDATA OPENconnectors Command Line Interace User manual
Transcript
config 2 config.zoning.addWwnMem Syntax Purpose addWwnMem zoneName wwn This command adds a WWN zone member to the specified zone in the work area. NOTE: A product can have at most 1024 zone members in its zones. NOTE: The ED-5000 supports a maximum of 512 zones. Parameters Command Example This command has two parameters. zoneName Specifies the name of the zone. wwn The WWN of the member to be added to the zone. The value of the WWN must be in colon-delimited hexadecimal notation (for example, AA:00:AA:00:AA:00:AA:00). Root> config zoning addWwnMem TheUltimateZone 10:00:00:00:C9:22:9B:64 config.zoning.addZone Syntax Purpose addZone zoneName This command adds a new (empty) zone to the zone set in the work area. NOTE: Changes are not activated on the switch until the config.zoning.activateZoneSet command is issued. NOTE: A zone set can have a maximum of 1024 zones. NOTE: A Switch or Director can have a maximum of 1024 zone members in all of its zones, except for the ED-5000, which allows a maximum of 512 zones. CLI Commands 2-87
Related documents
McDATA E/OS Command Line Interface User Manual
Brocade M-EOSc Command Line Interface User Manual
McDATA OPENconnectors Command Line Interace User manual
HP StorageWorks Director 2/64 base 32 port config CLI Reference Guide
McDATA OPENconnectors Command Line Interace Network Card User Manual
Manuel de l`utilisateur de HP Array Configuration Utility
Eclipse SAN Routers SRN Rev. B
EFCM Basic User Manual (v9.0.0)
McDATA EFCM Basic User Manual
Wordbooker User Guide Version 1.8 (June 2010