Download RAD Data comm LA-210 Specifications
Transcript
Appendix C Operation, Administration and Maintenance (OAM) Installation and Operation Manual Figure C-3. One Flow per UNI • In case of multiple flows per UNI (Figure C-4), PM and CC are transmitted three times. Figure C-4. Multiple Flows per UNI • In case of one flow and multiple CoS (Service Instances) per UNI (Figure C-5), the PM is transmitted three times and the CC – once. Figure C-5. One Flow and Multiple CoS (Service Instances) per UNI C.4 OAM Flows Figure C-6 illustrates a typical OAM traffic flow. The OAM message is transmitted from the source MEP 1 to the destination MEP 2 and the reply is transmitted back The source is also a destination for messages from the other direction. The OAM interval is one second, so each NTU transmits one request and one reply and receive one request and one reply. Total of four messages are transmitted per second per service instance. OAM Message Request MEP 1 Source MEP 2 OAM Message Reply Destination Figure C-6. OAM Flow OAM Messages Addressing The OAM defines two modes of addressing, unicast and multicast. Unicast addressing is used for point-to-point connections, while multicast addressing is C-4 OAM Flows LA-210 Ver. 1.5