Download Wells WVAE-55FS Operating instructions
Transcript
SAFETY PROCEDURES Knowledge of proper procedures is essential to the safe PRECAUTIONS & GENERAL INFORMATION 1. This ventilator hood system is designed as part of a operation of electrically energized equipment. In deep fat fryer system. No other use of this product is accordance with generally accepted product safety labeling authorized or recommended. guidelines for potential hazards, the following signal words and symbols are used throughout this manual. 2. This ventilator and attendant fryer are intended for use in commercial establishments where all operators Used to indicate the presence of a hazard are familiar with the appliance use, limitations, and which will cause severe personal injury, associated hazards. Operating instructions and death, or substantial property damage in warnings must be read and understood by all the event the statement is ignored. operators and users. Warning used to indicate the presence of a 3. This ventilator hood system is designed to reduce odor hazard which can cause personal injury and emissions, but will not completely eliminate cooking possibly death, or major property damage, odors. Air exchange at the installation site must in the event the statement is ignored. comply with the requirements of the local jurisdictional authority. To ensure that odors do not Caution is used to indicate the presence of a build up, recommended minimum air exchange is hazard which will or can cause minor 400 cfm (11,3m 3) into and out of the site. personal injury or property damage in the event the statement is ignored. 4. This equipment is made in the USA and has American size hardware. Used to indicate the presence of an electrical hazard which will or can cause 5. Any trouble shooting guides, component views or personal injury or property damage in the parts lists included in this manual are for general event the statement is ignored. reference only, and are intended for use by qualified technical personnel. NOTE Note is used to notify personnel of installation, operation, or maintenance 6. This manual should be considered a permanent part of information which is important but not this appliance. The manual with all supplied hazard related. instructions, diagrams, schematics, part breakdowns, notices, and labels must remain with the appliance if it is sold or moved to another location. HAZARD COMMUNICATION STANDARD (HCS) The procedure in this manual may include the use of chemical products. These chemical products will be highlighted with bold face letters followed by the abbreviation (HCS). See the Hazard Communications Standard section of this manual for the appropriate Material Safety Data Sheet(s). EQUIPMENT SET-UP PRECAUTIONS 1. Verify vertical clearances. Ventilator fryers require a minimum of 96" (244cm) floor to overhead to allow for adequate air circulation. 2. Verify that the ventilator hood assembly is properly and securely assembled to the fryer before beginning the installation procedure. 3. If a remote pull station is to be used, replace the rear casters with fixed legs. 4. Adjust the fixed legs with a spirit level until the unit is level front-to-back and side-to-side. Operation and Care Manual #8452/53/55 PG. 2