Download AML M3000 User`s guide
Transcript
M3000 Bar Code Reader User's Guide FUNC + SETUP Setup Selection (Continued) > Menu Level 1 > Menu Level 2 Bar Codes (Continued) Preamble Postamble ➡ Menu Level 3 ➡ Menu Level 4 Description (if required) ↵ Enter Preamble Send Delay 0-31 char. 0.0s - 9.9s Default = 0 0-31 char. 0.0s - 9.9s Default = 0 ↵ Enter Postamble Send Delay Bar Code Edit ↵ Editing Lead Strip Trail Strip Space Strip Code ON/OFF* 0 - 30, 0* 0 - 30, 0* ON/OFF* (See description) Default = ALL Editing affects ALL Bar Code types if ON, or the Bar Code selected at the Code option, No Bar Codes are affected if Editing is OFF. Valid Bar Codes are: Code 39, UPC-A, UPC-E, EAN13, EAN-8, I 2 OF 5, CODABAR, CODE 128, CODE 93, MSI, CODE 11, OR ALL. Bar Code Beeper ↵ Tone LOW-HIGHEST & NONE SHORTESTLONGEST Default = MEDIUM Timeout 1 Sec - 9 Sec & OFF Default = 1 Trigger Off Always Run Read Delay Bar Code ID Dupli Reads F1-F10 Keys Specl Keys ON*/OFF ON/OFF* 1.0s - 0.9s Default = 1.0 Length Laser/CCD Opts Other Options > Menu Level 1 Transmit Setup ↵ ↵ ➡ Menu Level 2 ➡ Menu Level 3 Data MENU*/SEND ALL Mode Dialing MENU* KBD WEDGE SER WEDGE RS232 PORT MODEM TONE*/PULSE Phone Number (Enter Dialing Text) Protocol NONE* XON/XOFF XMODEM Output ASCII* PCSCAN Baud Rate 300 600 1200 2400 4800 9600* 19200 38400 7 or 8* Data Bits 6-6 ↵ Default = SHORT ON/OFF* ON*/OFF ON/OFF* ON/OFF* Description (if required) Press ENTER to save dialing text.