Download Cisco PA-E3 Specifications
Transcript
Single Package Air Conditioners Installation Instructions 7. Start--up Procedures cess panel and is also published in the Technical Support Manual. Wire the speed tap as required. Electrical shock hazard. Cooling and Heating Use extreme care during all of the following checks and procedures. If an Electric Heat Accessory is used, see its Installation Manual for proper heating speed tap settings. If it has been determined that cooling and heating speeds are needed on the same speed tap, remove the red heating lead from the speed tap block and connect it to the insulated male terminal on the black cooling lead. Then place the insulated black female quick connect to the required speed tap. Make sure electric power is turned OFF as instructed in appropriate steps. Failure to follow this warning can result in property damage, personal injury, and/or death. Circulating Air Blower Determining Blower Speed 1. Turn electric power OFF. 2. From the system design, determine the external static pressure (ESP) for the supply ducts, return ducts and registers, diffusers, grilles, dampers, heaters and special filters (if any). 3. To your system ESP determined in Step 2, add 0.05 inches of Water Column for a wet coil and 0.08 inches of Water Column for the unit filter. 4 . From the system design, determine the desired cooling airflow in cubic feet per minute (CFM). 5. Locate the unit’s Blower Performance Data table in the tech data sheet for the unit’s voltage. (The tech data sheet is attached to the inside of the electrical access panel and is also published in the Technical Support Manual.) From the table, determine the speed tap the desired airflow requires. 6 . See next section, Speed Taps, to set the blower motor speed terminal block (speed taps) to the cooling speed determined in the previous steps. Speed Taps After determining the required CFM and speed tap data from the tech data sheet, follow the steps below to change speeds if necessary. NOTE: The yellow lead MUST always be connected to the speed tap block at the common quick connect terminal. The terminal is identified as COM. Also, this is the only lead which is 3/16² wide. All other quick connects are 1/4² wide. Cooling Only Check Before Starting 1. Check that the blower motor speed terminal block is set to the proper cooling speed. Refer to the unit wiring diagram and the various airflow tables in the Technical Support Manual. 2. Check to see that clean, properly sized field supplied air filters are installed in the return air duct. 3. Inspect the inside of the unit to be sure that all wires are in place and all tools, etc. are removed. 4. Replace all service access panels. Check the unit’s operation as outlined in the following instructions. If any unusual sparking, odors or noises are encountered, shut OFF electric power immediately. Recheck for wiring errors or obstructions in or near blower motors. Reverse Rotation (Scroll Compressors Only) Three phase scroll compressors CAN run in reverse if improperly wired. If the compressor makes an unusually loud noise, or if high and low side pressures are nearly identical, this indicates reverse rotation. To correct, reverse any two wires at line voltage connections ONLY. Do NOT rewire any circuits inside the unit to attempt correction of reverse rotation. Circulating Air Blower 1. Be sure electric power is OFF. 2. Set thermostat Heat--Cool selector to OFF. 3. Set thermostat fan switch to AUTO. Refer to FIGURE 7 on Page13 and the unit’s wiring diagram, which is attached to the inside of the electrical ac- 513 01 1702 00 11