Download iQ Sensor Solution Reference Manual
Transcript
CC-Link The following shows the devices supporting iQSS, iQ Sensor Solution functions, and supported version available for CC-Link. ■Mitsubishi Electric Corporation : Supported, : Not supported Type Model name module*1,*2 L26CPU-BT*3, iQ Sensor Solution function L26CPU-PBT*3 LJ61BT11*4 QJ61BT11N*5 Analog input module (voltage/current input) AJ65SBT2B-64AD*6 Analog input module (Temperature input) RTD AJ65SBT2B-64RD*7 Thermocouple AJ65SBT2B-64TD*8 CC-Link master/local Analog output module (Voltage/Current output) *1 *2 *3 *4 *5 *6 *7 *8 *9 AJ65SBT2B-64DA*9 The data backup/restoration function is supported by the module with a serial number of which the first five digits are '14112' or higher. The module with a serial number of which the first five digits are '15052' or higher supports the devices connected to communication unit for CC-Link. The module with a serial number of which the first five digits are '16042' or higher supports the devices supporting iQSS, which are connected to Bridge module (NZ2AW1C2AL). The module with a serial number of which the first five digits are '15052' or higher supports the devices supporting iQSS, which are connected to Bridge module (NZ2AW1C2AL). The module with a serial number of which the first five digits are '17012' or higher supports the functions. The module with a serial number '1211DB' or higher supports the functions. The module with a serial number '1211DC' or higher supports the functions. The module with a serial number '1211BC' or higher supports the functions. The module with a serial number '1211GC' or higher supports the functions. ■Panasonic Industrial Devices SUNX Co., Ltd. : Supported, : Not supported Type Model name Communication unit for CC-Link SC-GU3-01*1 Analog input unit *2 FX-301*3, FX-305, FX-501, FX-502 Digital laser sensor*2 LS-403 Head-separated dual display digital pressure sensor*2 DPS-401, DPS-402 *2 *3 SC-T1JA, SC-A01, SC-A02 Digital fiber sensor*2 *1 iQ Sensor Solution function The products manufactured from December, 2012 onward support the functions. A cascading connector unit (SC-71) is required separately. An end unit (SC-GU3-EU) is required separately. Use the dedicated software (SC-PC1) to configure the required settings. The unit/sensor supports each function by being connected to a communication unit for CC-Link (SC-GU3-01). A sensor head is required separately. The products manufactured from June, 2004 onward support the functions. APPENDICES APPENDIX Appendix 2 List of Device that Supports iQ Sensor Solution 171 A