Download IM Manual 2/18/04
Transcript
Chapter 4: Setting Up Stations and Sensors, continued Setting Inhibit Conditions These cells allow you to set the conditions under which watering will be interrupted (until the condition is no longer true) or canceled (for the remainder of the program). The possible values for the Inhibits When and Inhibits Limit cells are determined by what is entered in the sensor Use cell to the left. The cells to the right of the Limit cells display the unit of measure selected at the SETUP screen. To set inhibit conditions: 1. With the SENSOR SETUP screen displayed, Auto Stand-Alone SENSOR SETUP Type 1 S 2 S 3 S 4 P 5 P 6 P Use Freeze Rain – ET – MVs 1 2 3 01:16 pm Inhibits When Limit Closed Open 0.06 Amps 01/01/2001 Units Go to sensor– details Freeze sensor Page Down Sensor Details Clear Row Peripheral Setup use the arrow buttons to highlight the cell that corresponds to the sensor number and Inhibits When characteristic, then press to cycle through the following choices: Switch Sensors • Open (the default value) — The sensor stops watering when the sensor circuit is open. • Closed — The sensor stops watering when the sensor circuit is closed. Pulse Sensors Note: To set inhibit conditions for pulse sensors, you must first enter information about the pulse sensors on the SENSOR DETAILS screen. For more information, see Chapter 4, Setting Calibration for Pulse Sensors. 40 • Never (the default value) — The controller will never stop watering because of the sensor. • < (less than) — The sensor will stop watering when the value is less than the amount in the cell to the right. • > (greater than) — The sensor will stop watering when the value is greater than the amount in the cell to the right.