Parameter adjustment : Automatic Opening Mode (2/2)
Parameter
Adjustment
range
Door overtorque force
Door opening high
speed
Door opening
dampening speed
Opening acceleration
duration (OZ1)
Opening braking
threshold (OZ2)
Opening dampening
threshold (OZ3)
Chime duration on
opening
PSD setting
values
115 to 170 N
170 N
0.27 to 0.67 m/s 0.6 m/s
PED
setting
values
170 N
0.6 m/s
0.07 to 0.20 m/s 0.13 m/s
0.13 m/s
600 to 1100 ms 900 ms
900 ms
600 to 1100 mm TCL: 800 mm 1025 mm
AEL: 650 mm
650 to 1150 mm TCL: 900 mm 1075 mm
AEL: 700 mm
0.2 to 10 s
3s
3s
Preferable
adjustment mode
Influence on
mechanical strains
Modification of kinetic
energy values
Not applicable