Download Platform Screen Doors System Line and Workshop Maintenance

Transcript
Dismounting / Mounting - Electronical LRU (4/4)
Contract 554 - Platform Screen Doors System
Operating and Maintenance Manual - Vol. 2 - chap. 4
WORK INSTRUCTION
7.3
4 of 4
SLC 5/04 Control Processing Unit module
Use only lithium battery of the type and rating specified for the unit.
!
Case 3
DM - 86
7.
Plug the battery connector back in its socket.
8.
Re-insert the processor module as detailed above
Replacing a retainer clip
1.
If necessary pry off the broken retainer clip from the bottom with a screwdriver. Do not twist it
off. You may damage the module.
2.
Insert one of the pins of the retainer clip into the hole in the module and then snap the other end
in place.
DM_I94
DM_I95
Retainer Clip
Retainer Clip
Holding Tabs
figure DM 207 - retainer clip installation on module
8
Functional check
Proceed with paragraph 3.1 of functional check work instruction FC - 10.
rev. B - January 1998
4 - 434
2.Line Maintenance
Only paragraph 3.1 of work instruction FC-10 shall be applied
WORK
WORKINSTRUCTIONS
INSTRUCTION
B - 99
Platform Screen Doors • Line & Workshop Maintenance
1. General