Appendix C: TS100 Performance Checks
34. Press the Setup softkey.
35. When the Setup menu is displayed, press the Auto Control softkey. Note that
the softkey label changes to Manual Control.
36. Press the Test Type softkey.
37. When the Test Type menu is displayed, press the up arrow three times to highlight TEST PAIR.
38. Press the Exit softkey.
39. Press the Span softkey.
40. Press the up arrow once to increase the span beyond 2000 ft.
41. Move the cursor out to approximately 2000 ft using the right arrow.
42. Press the Gain softkey.
43. Press the up arrow until the gain, as shown in the dialog box on the display, is
50 dB, 20dB Attenuator: OFF.
44. Press the Vertical Position softkey.
45. If the automatic centering is not on (dialog box on the display will show Vertical Position [Manual] if it is not on), press the star key once to turn on auto–
centering and wait for the noise to center.
NOTE: Auto–centering at high gain could take several seconds to achieve.
85
Figure C-13: Noise
46. Note the height of the noise. It should be approximately 1/8 of the display
window. The display should look like Figure C-13.
TS100 TelScout User Manual
C–9