Download 24Volt I/O Junction Box for 24 Volt D
Transcript
Henkel Corporation One Henkel Way Rocky Hill, CT 06067 USA Phone 860.571.5174 Fax 860.571.5131 [email protected] 24Volt I/O Junction Box for 24 Volt D-Series Robots Part # 1461974 Description: The I/O Junction Box, item # 1461974 provides isolated I/O connections between 24 volt D-series robots and external devices such as solenoids and sensors. Includes: Qty 1 Description 24V Junction Box for D-Series Robot Important Instructions and Specifications: 1. CAUTION: Confirm that the D series robot to be used with the junction box is a 24 volt unit. If it is not, do not use this junction box or damage to the robot and/or junction box will result. 2. CAUTION: Cables cannot be connected or disconnected from the robot while the robot is on!!! If this occurs, the robot will be damaged. 3. CAUTION: Do not connect 24 volts to P_GND directly, (no load), or damage to I/O board may result. 4. Robot inputs must only be turned on by means of a dry contact switch. Do not apply voltage to robot input circuits. 5. Total output current from robot outputs should not exceed 250 mA. 6. Nominal coil current for relays: 15 mA 7. Relay contact rating: 3A @ 24 VDC 8. Note inverted robot input logic: robot detects input as low (0) when input is turned on, (opto-isolator is on). High (1) is the default state, (opto-isolator is off). 24 VOLT JUNCTION BOX INTERNAL LAYOUT +24 VOLTS FROM ROBOT TO ROBOT OPTO INPUT WHEN (CATHODE) JUMPED JUMPERS PASS +24 VOLTS FROM ROBOT TO INPUT CONNECTOR GROUND FROM ROBOT GREEN LEDS LIGHT WHEN RESPECTIVE OPTO-COUPLER IS ON 25 PIN I/O CONNECTOR TO ROBOT RED LEDS LIGHT WHEN RESPECTIVE RELAY COIL IS ON RELAYS (8) +24 VOLTS DIRECT FROM ROBOT RELAY CONNECTIONS JUMPERS PASS +24 VOLTS FROM ROBOT TO COM OF RESPECTIVE RELAY NC NO COM INPUT CIRCUITS EXAMPLE 1: TURN ON ROBOT INPUT #1 USING AN EXTERNAL DRY CONTACT SWITCH EXTERNAL SWITCH CONNECTION TO ROBOT INPUT #1 GROUND CONNECTION (USE ANY POSITION) 25 PIN I/O CONNECTOR TO ROBOT CONNECT INPUT #1 TO ONE SIDE OF THE EXTERNAL SWITCH CONNECT GROUND TO THE OTHER SIDE OF THE SWITCH INPUT CIRCUITS EXAMPLE 2: TURN ON ROBOT INPUT #1 USING A 24 VOLT DC LOW LEVEL SENSOR WITH PNP SOURCING OUTPUT RELAY COIL CURRENT MUST NOT EXCEED THE SENSOR OUTPUT LIMIT GROUND DIODE (MANDATORY) OUTPUT RELAY (24 VOLT COIL, 250mA MAX) +V SENSOR +24 VOLTS FROM ROBOT ROBOT INPUT # 1 CONNECTION GROUND CONNECTION (USE ANY POSITION) JUMP PINS AT POSITION 1 25 PIN I/O CONNECTOR TO ROBOT - PLACE A JUMPER ACROSS PINS AT "IN1" - CONNECT +V OF THE SENSOR TO THE ROBOT +24 VOLT CONNECTOR - CONNECT THE SENSOR GROUND TO THE JUNCTION BOX GROUND CONNECTOR - CONNECT THE SENSOR OUTPUT (COLLECTOR) TO RELAY COIL (+) - CONNECT THE (-) SIDE OF THE COIL TO THE ROBOT GROUND - INSTALL CLAMPING DIODE ACROSS RELAY COIL AS SHOWN INPUT CIRCUITS EXAMPLE 3: TURN ON ROBOT INPUT # 1 USING A 24 VOLT DC LOW LEVEL SENSOR WITH NPN SINKING OUTPUT RELAY COIL CURRENT MUST NOT EXCEED THE SENSOR OUTPUT LIMIT +V OUTPUT RELAY (24 VOLT COIL 250mA MAX) DIODE (MANDATORY) GROUND SENSOR +24 VOLTS FROM ROBOT ROBOT INPUT 1 CONNECTION GROUND CONNECTION (USE ANY POSITION) INPUT #1 JUMP PINS AT POSITION 1 25 PIN I/O CONNECTOR TO ROBOT - PLACE A JUMPER ACROSS PINS AT "IN1" - CONNECT +V OF THE SENSOR TO THE ROBOT +24 VOLT CONNECTOR - CONNECT THE SENSOR GROUND TO THE JUNCTION BOX GROUND CONNECTOR - CONNECT THE SENSOR OUTPUT (COLLECTOR) TO THE COIL (-) - CONNECT THE (+) SIDE OF THE COIL TO + 24 VOLTS - INSTALL CLAMPING DIODE ACROSS RELAY AS SHOWN OUTPUT CIRCUITS EXAMPLE 1: OPERATE A SOLENOID CONTROL VALVE USING ROBOT OUTPUT #1 AND THE ROBOT INTERNAL POWER SUPPLY GROUND CONNECTION (USE ANY POSITION) +24 VOLTS FROM ROBOT 25 PIN I/O CONNECTOR TO ROBOT 24 VOLT DC SOLENOID DO NOT EXCEED ROBOT OUTPUT CURRENT LIMIT OF 250 mA (TOTAL CURRENT, TAKING INRUSH INTO ACCOUNT) JUMP PINS OF "OUT 1" TURN ROBOT OUTPUT1 ON NO TO ENERGIZE SOLENOID RELAY CONNECTIONS DIODE (MANDATORY) - PLACE JUMPER ACROSS PINS AT "OUT 1" TO PUT +24 VOLTS ON COMMON (POLE) OF RELAY # 1 - CONNECT THE NORMALLY OPEN CONTACT OF OUTPUT #1 TO THE COIL (+) - CONNECT THE OTHER SIDE OF THE COIL (-) TO THE GROUND CONNECTION - PLACE CLAMPING DIODE ACROSS COIL AS SHOWN OUTPUT CIRCUITS EXAMPLE 2: OPERATE A SOLENOID CONTROL VALVE USING ROBOT OUTPUT #1 AND AN EXTERNAL POWER SUPPLY 25 PIN I/O CONNECTOR TO ROBOT RELAY CONNECTIONS TURN ROBOT OUTPUT1 ON TO ENERGIZE SOLENOID NO COM DIODE (MANDATORY) 24 VOLT DC SOLENOID DO NOT EXCEED OUTPUT CURRENT LIMIT OF EXTERNAL SUPPLY OR RELAY CONTACT RATINGS 24 VOLT DC EXTERNAL POWER SUPPLY - CONNECT THE +24 VOLTS FROM THE EXTERNAL SUPPLY TO THE COMMON OF RELAY #1 - CONNECT THE NORMALLY OPEN CONTACT OF OUTPUT #1 TO THE COIL (+) - CONNECT THE OTHER SIDE OF THE COIL (-) TO THE GROUND OF THE EXTERNAL SUPPLY - PLACE CLAMPING DIODE ACROSS COIL AS SHOWN ROBOT CONNECTOR PIN ASSIGNMENTS: Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 Description IN # 1 IN # 2 IN # 3 IN # 4 IN # 5 IN # 6 IN # 7 IN # 8 NC NC COM GND COM GND COM GND Pin # 14 15 16 17 18 19 20 21 22 23 24 25 Henkel Corporation One Henkel Way Rocky Hill, CT 06067-3910 Henkel Canada Corporation 2225 Meadowpine Boulevard Mississauga, Ontario L5N 7P2 Henkel Corporation Automotive / Metals HQ 32100 Stephenson Hwy. Madison Heights, MI 48071 Henkel Ltda. Rua Karl Huller, 136 – Jd. Canhema 09941-410 Diadema/SP, Brazil Description OUTPUT # 1 OUTPUT # 2 OUTPUT # 3 OUTPUT # 4 OUTPUT # 5 OUTPUT # 6 OUTPUT # 7 OUTPUT # 8 NC NC +24V +24V Henkel Capital, S.A. de C.V. Calzada de la Viga s/n Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepac de Morelos, Edo. de México www.loctite.com ® and ™ designate trademarks of Henkel Corporation or its affiliates. ® = registered in the U.S. and elsewhere. © Henkel Corporation, 2009. All rights reserved. Data in these instructions is subject to change without notice. Manual P/N: 8902562, Rev A, Date: 03/2011