FN=32
SN=1
SN=2
FN=33
SN=1
SN=2
FN=41
SN=1
SN=2
FN=42
SN=1
SN=2
FN=43
SN=1
SN=2
FN=44
SN=1
SN=2
SN=3
FN=45
SN=1
SN=2
FN=46
SN=1
SN=2
FN=47
SN=1
SN=2
SN=3
SN=4
FN=48
SN=1
SN=2
SN=3
SN=4
FN=51
SN=1
SN=2
SN=3
SN=4
SN=5
SN=6
SN=7
SN=8
FN=52
SN=1
SN=2
SN=3
SN=4
FN=53
SN=1
SN=2
FN=54
SN=1
SN=2
SN=3
SN=4
FN=64
SN=1
SN=2
FN=65
SN=1
SN=2
SN=3
SN=4
NN=5
FN=66
SN=1
SN=2
SN=3
FN=67
SN=1
SN=2
SN=3
SN=4
FN=68
SN=1
Feature: INPUT 'DOORS (+ / –)'.
If voltage on input is +12 V, the system identifies the door open, if 0 V or input is not connected, the system identifies the door is closed.
If the voltage on input is 0 V, the system identifies the door is open, if +12 V or input is not connected, the system identifies the door is closed.
Feature: NON-RESPONSE TIME AFTER ARMING.
Non-response time is 5 seconds. Ignition, engine bonnet, luggage compartment, door switches and sensor monitoring starts after 5 seconds of alarm arming.
Non-response time is 45 seconds. Ignition, engine bonnet, luggage compartment, door switches and sensor monitoring starts after 45 seconds of alarm arming.
Feature: AUTOMATIC AND MANUAL LEARNING: DELAY OF ALARM SIGNAL.
The system delays alarm signal by door or sensor trigger for 1 second and waits for disarm pulses. The alarm signal is ON after a 1 second if there are no pulses.
The system extends delay for 5 seconds if pulses appear. The system turns ON alarm signal with the 5 second time is elapsed if disarm pulses were wrong.
The delay of alarm signal is turned OFF.
Feature: MANUAL LEARNING: ARMING PERMISSION / PROHIBITION.
Arming is permitted while voltage level on input 'CONDITION1' meet voltage level set by FN=47 and 5 seconds after it.
Arming is prohibited while voltage level on input 'CONDITION1' meet voltage level set by FN=47 and 5 seconds after it.
Feature: MANUAL LEARNING: DISARMING PERMISSION / PROHIBITION.
Disarming is permitted while voltage level on input 'CONDITION2' or 'CONDITION1' (FN=54, SN=2, 3) meet voltage level set by FN=48 and 5 seconds after it.
Disarming is prohibited while voltage level on input 'CONDITION2' or 'CONDITION1' (FN=54, SN=2, 3) meet voltage level set by FN=48 and 5 seconds after it.
Feature: AUTO-REARM.
Turned OFF. Auto-rearm function is not operated after alarm disarming.
The system will be armed automatically if within 45 seconds after disarming ignition remains not turned ON, doors, bonnet and luggage compartment remain unopened.
If during preset time (time till 45 seconds, set by-opening-closing the door, actions indication – short beeps of siren) after disarming the doors are opened and closed
system will be armed automatically.
Feature: AUTOMATIC LEARNING: ALARM SYSTEM DISARM PARAMETER.
Read out time of disarm pulses during automatic learning is limited till 2 seconds (must be set before automatic learning procedure).
Read out time of disarm pulses during automatic learning is limited till 5 seconds (must be set before automatic learning procedure).
Feature: THE WAY OF ALARM SYSTEM LEARNING.
Computer or automatic learning.
Manual learning.
Feature: MANUAL LEARNING: ARMING PERMISSION / PROHIBITION LEVEL.
High. Voltage level on input 'CONDITION1' no less 1.2 V.
High. Voltage level on input 'CONDITION1' no less 4.0 V.
Low. Voltage level on input 'CONDITION1' no more 1.2 V.
Low. Voltage level on input 'CONDITION1' no more 4.0 V.
Feature: MANUAL LEARNING: DISARMING PERMISSION / PROHIBITION LEVEL.
High. Voltage level on input 'CONDITION2' (FN=54, SN=1) or on input 'CONDITION1' (FN=54, SN=2, 3) no less 1.2 V.
High. Voltage level on input 'CONDITION2' (FN=54, SN=1) or on input 'CONDITION1' (FN=54, SN=2, 3) no less 4.0 V.
Low. Voltage level on input 'CONDITION2' (FN=54, SN=1) or on input 'CONDITION1' (FN=54, SN=2, 3) no more 1.2 V.
Low. Voltage level on input 'CONDITION2' (FN=54, SN=1) or on input 'CONDITION1' (FN=54, SN=2, 3) no more 4.0 V.
Feature: OPTIONAL CONTROL PURPOSE.
Optional control is used as input for secret button (–).
Additional immobilization. Optional control is used to control a relay (with normally open contacts) cutting-off starter control circuit.
Out of use.
40 second negative polarity pulse generated upon arming and designed for closing of power windows and / or sunroof.
If any door, engine bonnet, luggage compartment is opened with alarm enabled, inner (alarm) zone of the sensor is triggered generating pulse signal for pager
message.
If any door, engine bonnet, luggage compartment is opened with alarm enabled, inner (alarm) or outer (pre-alarm) zone of the sensor is triggered generating pulse
signal for pager message.
Optional control is used for communication with GSM communicator GSW1.
The negative polarity constant signal is generated with the system is armed and is switched OFF with the system is disarmed.
Feature: AUTOMATIC LEARNING: PULSE DURATION TOLERANCE.
The pulse duration tolerance is ±30%.
The pulse duration tolerance is ±50%.
The pulse duration tolerance is ±70%.
The pulse duration tolerances are –100%; +120%.
Feature: INNER IMOBILIZER*.
The engine is immobilized with system is disarmed and ignition is turned ON. For immobilization cancelling press the secret button / turn ON (place) ID card.
Inner immobilizer turned OFF.
Feature: INPUT 'CONDITION2'.
Input for signal 'CONDITION2'
Input for secret button (+).
Serial input for communication with IMB5.
Automatic learning (in accordance with 3 g).
Feature: SIGNAL ON ARMING WITH SENSOR BYPASS.
Out of use.
0.3 second siren signal.
Feature: TYPE OF SIREN AND ARMING / DISARMING CONFIRMATION SIGNAL LEVEL.
Horn type siren (speaker with coil impedance at least 4 Ohm). Maximum sound level.
Horn type siren (speaker with coil impedance at least 4 Ohm). Sound level reduced 2 times
Horn type siren (speaker with coil impedance at least 4 Ohm). Sound level reduced 4 times.
Horn type siren (speaker with coil impedance at least 4 Ohm). Sound level reduced 8 times.
Electronic siren controlled by voltage, with inner modulation.
Feature: SIREN SIGNAL ON ARMING OR DISARMING.
Silent. Arming and disarming with no siren signal.
Loud. Arming and disarming with sound signals.
Loud. Acting as SN=2, but if the alarm system has alarmed in armed state, 4 sound beeps are generated.
Feature: WARNING MELODY ON TRIGGERING OF THE OUTER (PRE-ALARM) ZONE OF THE SENSOR.
Melody 1 (using the horn type siren).
Melody 2 (using the horn type siren).
Melody 3 (using the horn type siren).
Melody 4 (using the horn type siren).
Feature: DIRECTION INDICATORS ON ARMING OR DISARMING.
Direction indicators do not react.
GN6I.a
ES
FEATURE