RF100 Series I/O Board Specifications (optional) Available Channels 1 - Dedicated Analog Input (AI) 2 - Selectable Analog Input (AI) or Output (AO) 3 - Dedicated Discrete Input (DI) 4 - Selectable Discrete Input (DI) or Output (DO) 5 - Dedicated Discrete Output (DO) Configurations (Selectable) • 1-AO, 1-AI, 2-DI, 1-DO • 1-AO, 1-AI, 1-DI, 2-DO • 2-AI, 2-DI, 1-DO • 2-AI, 1-DI, 2-DO Classification FCC Class A and CISPR 22 computing device Analog Input Quality/Type: Single-ended, voltage-sense analog inputs (current loop if scaling resistor is used). Signal: 1 to 5 Vdc, software configurable. 4 to 20 mA, with 250W resistor installed across “+” and “-” terminals. Terminals • AI1 or AI2 (+) Positive Input • ACOM (-) Negative Input (common) Accuracy: 0.5% over -40 to 149°F (-40 to 65°C) range. Isolation: None Input Impedance: 1MW Filter: Single pole Resolution: 10 bits Conversion Time: 200 µs Sample Period: 1.0-second minimum Analog Output Quality/Type: 0 to 2 Vdc output or 4 to 20 mA current Terminals • AO (+) Positive Output • ACOM (-) Negative Output (common) Resolution: 8 bits Accuracy: 0.5% of full-scale output Reset Action: Output goes to last value (software configurable) on power-up (warm start) or on watchdog time-out Discrete Input Quality/Type: Contact-sense discrete input or voltage sourced 3.3 to 24 Vdc Terminals • DI1 or DI2 (+) Positive Input • DCOM (-) Negative Input (common) Current Rating: 35 µA in the active (on) state, 0 µA in the inactive (off) state Isolation: None Frequency: 0.5 Hz maximum Sample Period: 1.0 second minimum Discrete Output Quality/Type: Solid-state switch Terminals • DO1 or DO2 (+) normally-open contact • DCOM (-) common Switch Rating: 24Vdc @ 12 mA maximum or 12 Vdc @ 10 mA maximum Environmental Meets the Environmental specifications of the RegFlo units in which the board is installed. RTD Interface (optional) RTD Input Quantity/Type: Single input for a 2, 3 or 4-wire RTD element with alpha of 0.00385 Sensing Range: -40 to 167°F (-40 to 75°C) Introduction Scope of Manual This instruction manual provides generalized guidelines for successful installation and operation of the RegFlo RF100 Series flow and pressure instruments. Planning helps to ensure smooth installation. Be sure to consider location, ground conditions, climate, and site accessibility as well as the suitability of the application when planning an installation. Refer to the appropriate Accuracy: ±1.0°F (-18° to -17°C) over sensing range (includes linearity, hysteresis, repeatability). Resolution: 16 bits. Sample Period: 1 sec minimum. instruction manuals when installing and maintaining regulators and other equipment used with the RF100 Series instruments. Product Description The RF100 Series pressure and flow instruments are devices which measure and archive flow and pressure data. The Type RF110 instrument is used as a standalone pressure recorder. The Type RF100 instrument is mounted on a regulator, such as a Type EZR and 3