Download E3X-ECT
Transcript
A Appendix A-1-6 Sync Manager Communication Object The communication memory of EtherCAT is set by the objects from 1C00 hex to 1C13 hex. 1C00 hex Sync Manager Communication Type Sub-index 0: Number of used SM channels Range: Unit: Size: 1 byte (U8) Attribute: Default: 04 hex Access: RO PDO map: Not possible Sub-index 1: Communication Type Sync Manager 0 Range: Unit: Size: 4 bytes (U8) Attribute: Default: 01 hex Access: RO PDO map: Not possible Sub-index 2: Communication Type Sync Manager 1 Range: Unit: Size: 4 bytes (U8) Attribute: Default: 02 hex Access: RO PDO map: Not possible Sub-index 3: Communication Type Sync Manager 2 Range: - Unit: - Size: 4 bytes (U8) Default: 03 hex Access: RO Attribute: PDO map: Not possible Sub-index 4: Communication Type Sync Manager 3 Range: - Unit: - Size: 4 bytes (U8) Default: 04 hex Access: RO Attribute: PDO map: Not possible • The sync manager has the following settings. • SM0 : Mailbox receive (EtherCAT Master Unit to Slave Unit) • SM1 : Mailbox transmit (EtherCAT Slave Unit to Master Unit) • SM2 : Process data output (EtherCAT Master Unit to Slave Unit) • SM3 : Process data input (EtherCAT Slave Unit to Master Unit) 1C10 hex Sync Manager 0 PDO Assignment Sub-index 0: Number of assigned PDOs Range: 00 hex Size: 1 byte (U8) Unit: Attribute: Default: 00 hex Access: RO PDO map: Not possible • It indicates the number of PDO mappings used by this sync manager. • Mailbox reception sync manager does not have PDOs. A-1 Object Dictionary A A-1-6 Sync Manager Communication Object E3X-ECT EtherCAT Sensor Communication Unit Instraction Manual A - 11