336 Process Control Instruction Runtime Errors Error Code 11H Error code 0036 appears in the status file when a PID instruction runtime error occurs. Code 0036 covers the following PID error conditions, each of which has been assigned a unique single byte code value that appears in the MSB of the second word of the control block. The error code is also displayed on the PID Setup Screen in RSLogix 500. Description of Error Condition or Conditions 1. Loop update time Dt > 1024 Corrective Action Change loop update time 0 < Dt < 1024 2. Loop update time Dt = 0 12H Proportional gain Kc < 0 Change proportional gain Kc to 0 < Kc 13H Integral gain (reset) Ti < 0 Change integral gain (reset) Ti to 0 < Ti 14H Derivative gain (rate) Td < 0 Change derivative gain (rate) Td to 0 < Td 15H Feed Forward Bias (FF) is out-of-range. Change FF so it is within the range -16383 to +16383. 23H Scaled setpoint min MinS > Scaled setpoint max MaxS Change scaled setpoint min MinS to -32768 < MinS < MaxS < +32767 31H If you are using setpoint scaling and MinS > setpoint SP > MaxS, or If you are using setpoint scaling, then change the setpoint SP to MinS < SP < MaxS, or If you are not using setpoint scaling and 0 > setpoint SP > 16383, If you are not using setpoint scaling, then change the setpoint SP to 0 < SP < 16383. then during the initial execution of the PID loop, this error occurs and bit 11 of word 0 of the control block is set. However, during subsequent execution of the PID loop if an invalid loop setpoint is entered, the PID loop continues to execute using the old setpoint, and bit 11 of word 0 of the control block is set. 41H 51H Scaling Selected Scaling Deselected 1. Deadband < 0, or 1. Deadband < 0, or 2. Deadband > (MaxS – MinS) 3. Deadband > 16383 1. Output high limit < 0, or Scaling Selected Scaling Deselected Change deadband to 0 < deadband < (MaxS - MinS) < 16383 Change deadband to 0 < deadband < 16383 Change output high limit to 0 < output high limit < 100 2. Output high limit > 100 52H 1. Output low limit < 0, or 53H Output low limit > output high limit Change output low limit to 0 < output low limit < output high limit < 100 2. Output low limit > 100 Publication 1762-RM001F-EN-P - October 2009 Change output low limit to 0 < output low limit < output high limit < 100
Related documents
1762-RM001 - Rockwell Automation
MicroLogix™ 1200 and MicroLogix 1500 Programmable Controllers
1769-UM006 - Rockwell Automation
KDN-K3 CPU支持的数据类型位串类型及数值类型两种
Allen-Bradley 1794-IE8H Specifications
1762-RM001B-US-P, MicroLogix™ 1200 and MicroLogix 1500
Arquivos de Dados - Apostilas técnicas
1763-RM001 - Rockwell Automation
Compact I/O 1769-ADN DeviceNet Adapter
Additional Resources
1769-UM001 - Rockwell Automation
Multi-Channel High Speed Counter