Download Single Loop Controller YS1000 Series

Transcript
Terminal Block
YS1700/YS1500 Terminal Arrangements
Terminal
No.
1
2
3
4
5
6
7
8
9
10
11
12
YS1700
Programmable mode
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
Analog input 1
(1-5V DC)
Analog input 2
(1-5V DC)
Analog input 3
(1-5V DC)
Analog input 4
(1-5V DC)
Analog input 5
(1-5V DC)
Fail output
YS1310/YS1350/YS1360 Terminal Arrangements
YS1700/YS1500
Single-loop mode
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
PV
(1-5V DC)
Cascade set point input
(1-5V DC)
Tracking input
(1-5V DC)
Feedforward input
(1-5V DC)
Direct input signal
output (*1)
Fail output
Cascade mode
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
PV1
(1-5V DC)
Cascade set point input
(1-5V DC)
PV2
(1-5V DC)
Feedforward input
(1-5V DC)
Direct input signal
output (*1)
Fail output
Selector mode
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
Terminal
No.
PV1
1
(1-5V DC)
2
Cascade set point input 1
3
(1-5V DC)
4
PV2
5
(1-5V DC)
6
Cascade set point input 2
7
(1-5V DC)
8
Direct input signal
9
output (*1)
10
11
Fail output
12
YS1310
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
YS1350
⫹
⫺
⫹
⫺
PV1
(1-5V DC)
PV2
(1-5V DC)
⫹
⫺
⫹
⫺
Direct input signal
output (*1)
Fail output
YS1360
PV1
(1-5V DC)
Cascade set point input
(1-5V DC)
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
Direct input signal
output (*1)
Fail output
PV1
(1-5V DC)
Cascade input
(1-5V DC)
Direct input signal
output (*1)
Fail output
13 Transmitter Power supply (24V DC) Transmitter Power supply (24V DC) Transmitter Power supply (24V DC) Transmitter Power supply (24V DC)
13 Transmitter Power supply (24V DC) Transmitter Power supply (24V DC) Transmitter Power supply (24V DC)
14 Communication SG
Communication SG
Communication SG
Communication SG
14 Communication SG
Communication SG
Communication SG
15 Communication SDA (⫺)
Communication SDA (⫺)
Communication SDA (⫺)
Communication SDA (⫺)
15 Communication SDA (⫺)
Communication SDA (⫺)
Communication SDA (⫺)
16 Communication SDB (⫹)
Communication SDB (⫹)
Communication SDB (⫹)
Communication SDB (⫹)
16 Communication SDB (⫹)
Communication SDB (⫹)
Communication SDB (⫹)
17 Communication RDA (⫺)or LCS (⫹) Communication RDA (⫺)or LCS (⫹) Communication RDA (⫺)or LCS (⫹) Communication RDA (⫺)or LCS (⫹)
17 Communication RDA (⫺)
Communication RDA (⫺)or LCS (⫹) Communication RDA (⫺)or LCS (⫹)
18 Communication RDB (⫹)or LCS (⫺) Communication RDB (⫹)or LCS (⫺) Communication RDB (⫹)or LCS (⫺) Communication RDB (⫹)or LCS (⫺)
18 Communication RDB (⫹)
Communication RDB (⫹)or LCS (⫺) Communication RDB (⫹)or LCS (⫺)
19
20
⫹
⫺
Direct input (*1)
⫹
⫺
Direct input (*1)
⫹
⫺
Direct input (*1)
⫹
⫺
19
Direct input (*1)
21
N
G
Ground (GND)
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
L
⫹
⫺
Direct input (*1)
⫹
⫺
Direct input (*1)
Direct input (*1)
21
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
22
20
⫹
⫺
Analog output 1
(4앑20mA DC)
Analog output 2
(1-5V DC)
Analog output 3
(4앑20mA DC/1-5V DC)
Degital output 1 or
Degital input 6
Degital output 2 or
Degital input 5
Degital output 3 or
Degital input 4
Degital output 4 or
Degital input 3
Degital output 5 or
Degital input 2
Degital output 6 or
Degital input 1
Power supply
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
MV1
(4앑20mA DC)
MV2
(1-5V DC)
SV
(1-5V DC)
PV1 high limit alarm
output
PV1 low limit alarm
output
Deviation alarm output
C/A·M status output
C·A/M status output
Action mode switching
input
Power supply
Ground (GND)
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
MV1
(4앑20mA DC)
MV2
(1-5V DC)
SV
(1-5V DC)
First loop alarm output
Second loop alarm output
O/C status output
C/A·M status output
C·A/M status output
Action mode switching
input
Power supply
Ground (GND)
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
MV1
22
(4앑20mA DC)
23
MV2
24
(1-5V DC)
25
SV
26
(1-5V DC)
27
N
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
G
Ground (GND)
28
First loop alarm output
29
30
Second loop alarm output
31
32
L/R status output
33
34
C/A·M status output
35
36
C·A/M status output
37
Action mode switching
38
input
39
L
Power supply
Ground (GND)
⫹
⫺
⫹
⫺
⫹
⫺
Alarm output 1
Alarm output 2
⫹
⫺
⫹
⫺
SV
(1-5V DC)
PV1 high limit alarm
output
PV1 low limit alarm
output
Alarm output 3
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
Alarm output 4
Alarm output 5
Alarm output 6
or Degital input 1
Power supply
C/M status output
Input for LCD backlight off
Action mode switching
input
Power supply
Ground (GND)
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
MV1
(4앑20mA DC)
MV2
(1-5V DC)
PV1 high limit alarm
output
PV1 low limit alarm
output
C/M status output
Input for LCD backlight off
Action mode switching
input
Power supply
Ground (GND)
*1: Only applicable for YS100 compatible terminal type (“2” “4” “5”)
YS1000 Series (Basic Type) Terminal Block
YS010 Expandable I/O Terminal Arrangements
Terminal
number
1
2
3
4
5
6
7
8
9
10
11
12
쎲 Our product names or brand names mentioned in this manual are the trademarks or registered
trademarks of YOKOGAWA Electric Corporation (hereinafter referred to as YOKOGAWA).
쎲 Microsoft, MS-DOS, Windows, Windows XP, and Windows NT are either registered trademarks or
trademarks of Microsoft Corporation in the United States and/or other countries.
쎲 Ethernet is a registered trademark of XEROX Corporation.
쎲 We do not use the TM or (r) mark to indicate these trademarks or registered trademarks in this
user’s manual.
쎲 All other product names mentioned in this user’s manual are trademarks or registered
trademarks of their respective companies.
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Expandable I/O
Terminal
Analog input 6
Analog input 7
Digital input 7
Digital input 8
Digital input 9
Digital input 10
Terminal
number
13
14
15
16
17
18
19
20
21
22
23
24
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
⫹
⫺
Expandable I/O
Terminal
Analog input 8
Analog output 4
(1 to 5VDC)
Digital output 7
Digital output 8
Digital output 9
Digital output 10
11