Download Operator`s Manual
Transcript
Archangel Ph.C SECTION 4 Diag...(nostics) System (Diagnostics) When Diag is selected the following screen is displayed. When System is selected the following screen is displayed. Demonstration Modes Volts The demonstration modes are provided primarily for sales personnel. This display gives an indication of the voltage level of the +5, -5, +12 and -12 V power supplies and is provided as a diagnostic tool. The voltages should be within ±5% of the nominal level. Off Mode not enabled Unstdy Marker Four markers are superimposed on the input picture. After processing through Archangel One, the amount of movement of the markers is indicative of the amount of correction Archangel One is performing. This is especially useful for demonstrating the effectiveness of Archangel One with a single monitor. Temp Unstdy Graph When the temperature limit is approached, an intermittent chirp will be heard from the box. A continuous beep will be heard when the maximum range is exceeded. The unit will continue to run and will not automatically shut down if the maximum temperature is reached, however it is advised that the unit should be turned off at the first opportunity. The measured horizontal and vertical motion is displayed on a graph, with history detailing the last 250 fields. A vertical line on the graph indicates a detected cut. Note that Archangel One will not correct unsteadiness when the graphs are displayed. Graph H-Gain The horizontal gain of the graph may be adjusted using this control. If the unit is overheating, check that the ventilation fan is operating on the rear of the unit and the airflow is not restricted by external objects or the build-up of dust/dirt in the fan grille. Alarms Graph V-Gain The vertical gain of the graph may be adjusted using this control. Valid Blocks (Diagnostics) The temperature warning beep can be disabled by setting the temperature alert in the Alarms menu to Off. This overlay shows the regions of the screen that the unsteadiness process is using in its calculations. ARCHOPS 171104 www.snellwilcox.com Version 1 Issue 4 4.13