Download Manual - Proware

Transcript
iSCSI GbE to SAS/SATA II RAID Subsystem
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
INFO
INFO
INFO
INFO
š
SATA PRD mem
fail
SATA revision id
fail
SATA set reg fail
SATA init fail
SATA diag fail
Mode ID fail
SATA chip count
error
SAS port reply
error
SAS unknown port
reply error
FC port reply error
FC unknown port
reply error
Failed to init SATA PRD memory manager
Failed to get SATA revision id
Failed to set SATA register
Core failed to initialize the SATA adapter
SATA Adapter diagnostics failed
SATA Mode ID failed
SATA Chip count error
SAS HBA port <number> reply terminated
abnormally
SAS frontend reply terminated abnormally
FC HBA port <number> reply terminated
abnormally
FC frontend reply terminated abnormally
EMS events
Level
INFO
ERROR
INFO
ERROR
WARNING
INFO
ERROR
INFO
ERROR
ERROR
WARNING
ERROR
ERROR
Type
INFO
WARNING
ERROR
ERROR
Power install
Power absent
Power restore
Power fail
Power detect
Fan restore
Fan fail
Fan install
Fan not present
Fan over speed
Thermal level 1
Thermal level 2
Thermal level 2
shutdown
Thermal level 2
CTR shutdown
Thermal ignore
value
Voltage level 1
Voltage level 2
Voltage level 2
shutdown
Voltage level 2
CTR shutdown
UPS OK
UPS fail
UPS AC loss
UPS power low
WARNING
SMART T.E.C.
WARNING
SMART fail
ERROR
WARNING
WARNING
ERROR
ERROR
ERROR
Description
Power(<string>) is installed
Power(<string>) is absent
Power(<string>) is restored to work.
Power(<string>) is not functioning
PSU signal detection(<string>)
Fan(<string>) is restored to work.
Fan(<string>) is not functioning
Fan(<string>) is installed
Fan(<string>) is not present
Fan(<string>) is over speed
System temperature(<string>) is higher.
System Overheated(<string>)!!!
System Overheated(<string>)!!! The system will
auto-shutdown immediately.
The controller will auto shutdown immediately,
reason [ Overheated(<string>) ].
Unable to update thermal value on <string>
System voltage(<string>) is higher/lower.
System voltages(<string>) failed!!!
System voltages(<string>) failed!!! The system
will auto-shutdown immediately.
The controller will auto shutdown immediately,
reason [ Voltage abnormal(<string>) ].
Successfully detect UPS
Failed to detect UPS
AC loss for system is detected
UPS Power Low!!! The system will auto-shutdown
immediately.
Disk <slot> S.M.A.R.T. Threshold Exceed
Condition occurred for attribute <string>
Disk <slot>: Failure to get S.M.A.R.T information
User Manual
135