Download (ADC 2000) - Aptecelectronics.com

Transcript
IM2830
IM2830LG.doc, DIR. 962830
Shadin
INSTALLATION MANUAL
FUEL/AIRDATA COMPUTER
P/N 962830-1, 962830-2, 962830-3
Rev: J
2.0
FUEL AND AIRDATA SYSTEM SPECIFICATIONS
2.1
Input Data Range
Pitot
Static
OAT
Heading
Fuel Flow
K Factor
2.2
Output Data Range
PARAMETER
IAS
P.ALT
P.ALT
P.ALT
P.ALT
OAT
HEADING
IVS
TAS
MACH
WIND SPEED
WIND DIRECTION
FUEL FLOW
2.3
20 to 350 kts.
-1000 to 55,000 ft.
-60°C to, +60°C
0 - 360°
1 to 450 GPH Range Selected
500 to 130000 PPG Continuous
Accuracy
±1 kts.
±25 ft.
±30 ft.
±40 ft.
±100 ft.
±2°C
±1°
±40 ft./min.
±2 kts.
±.01
±1 kts.
±5°
±2%
RANGE
20 to 350 kts.
–1000 to 5000 ft.
5000 to 11000 ft.
11000 to 30000 ft.
30000 to 55000 ft.
–60°C to +60°C
0 - 360 degrees
± 10,000 ft./min.
20 - 600 kts.
.2 - .95
5 - 360 kts.
0 - 360 degrees
1 - 450 GPH
Dimensions (including mounting rack)
Size: 7.4" L x 4.3" H x 3.9" W
Weight: 36 oz.
2.4
Power Requirements
System Power required: 28 VDC @ 1300 mA
14 VDC @ 900 mA
Page: 2-1