Download Preface - Sion electronics

Transcript
216
Optional Components
11.6.2
AC input reactor
AC input reactor is mounted at input terminal of inverter to restrain transmitting harmonic
generated by inverter to power grid, reduce interference of inverter harmonic to other
components, improve quality of power grid, improve power factors and restrain abnormal
fluctuations of power grid voltage and surge current of power grid, stabilize waveform and
reduce impact to inverter.
…
…
Performance index of AC input reactor
•
Rated operational voltage: 380V/50Hz;
•
Dielectric strength: iron core-winding 3000VAC/50Hz/5mA/60S, no flashover breakdown;
•
Insulation resistance: iron core-winding 1000VDC, insulation resistance ≥100MΩ;
•
Reactor noise is less than 70dB (test at the point of 1m horizontal distance with reactor);
•
Temperature rise is less than 70K.
Mechanical parameter & configuration parameter of AC input reactor
Inverter
Power (KW)
Reactor Model
Dimensions
(Length X Width
X Height) (mm)
Mounting
Dimension
(mm)
Terminal
Bore
Diameter
(mm)
1.1
AKSG-10A/5V
140*75*145
75*55
φ6
1.5
AKSG-10A/5V
140*75*145
75*55
φ6
2.2
AKSG-10A/5V
140*75*145
75*55
φ6
3.0
AKSG-15A/5V
140*75*145
75*55
φ6
4.0
AKSG-15A/5V
140*75*145
75*55
φ6
5.5
AKSG-15A/5V
140*75*145
75*55
φ6
7.5
AKSG-20A/5V
170*150*135
80*70
φ6
9.0
AKSG-30A/5V
170*150*135
80*70
φ6
11.0
AKSG-30A/5V
170*150*135
80*70
φ6
15.0
AKSG-40A/5V
170*150*135
80*70
φ6
V350 Low-Power Closed-Loop Vector Inverter User Manual