Download User Manual - Quad Industry

Transcript
Datalinks
Values
See page 16 for symbol descriptions
300 [Data In A1] - Link A Word 1
301 [Data In A2] - Link A Word 2
Parameter number whose value will be written
from a communications device data table. Value
will not be updated until drive is stopped.
Refer to your communications option manual for
datalink information.
302 [Data In B1] - Link B Word 1
303 [Data In B2] - Link B Word 2
Default:
0 (0 = “Disabled”)
Min/Max:
Units:
0/611
1
304 [Data In C1] - Link C Word 1
305 [Data In C2] - Link C Word 2
See [Data In A1] - Link A Word 1 [Data In A2] Link A Word 2.
306 [Data In D1] - Link D Word 1
307 [Data In D2] - Link D Word 2
Not available with Liquid-Cooled drives.
308
v6 [HighRes Ref]
Used as a high resolution, 32 bit reference with
Datalinks.
–/+[Maximum Freq] or
–/+[Maximum Speed] = 32767 x 65536
See [Data In A1] - Link A Word 1 [Data In A2] Link A Word 2.
See [Data In A1] - Link A Word 1 [Data In A2] Link A Word 2.
Default:
0
Min/Max:
Units:
–/+2147418112
1
DPI
P
DPI ort 6 (1
)
P
DPI ort 5
Por
DPI t 4
P
DPI ort 3
P
DPI ort 2
P
Hos ort 1
t
Sec
urit
y
COMMUNICATIONS
310 [Data Out A1] - Link A Word 1
0 (0 = “Disabled”)
Default:
311 [Data Out A2] - Link A Word 2
Min/Max: 0/611
Parameter whose value will be written to a
1
Units:
communications device data table.
312 [Data Out B1] - Link B Word 1
See [Data Out A1] - Link A Word 1 [Data Out
313 [Data Out B2] - Link B Word 2
A2] - Link A Word 2.
314 [Data Out C1] - Link C Word 1
See [Data Out A1] - Link A Word 1 [Data Out
315 [Data Out C2] - Link C Word 2
A2] - Link A Word 2.
316 [Data Out D1] - Link D Word 1
See [Data Out A1] - Link A Word 1 [Data Out
317 [Data Out D2] - Link D Word 2
A2] - Link A Word 2.
595 [Port Mask Act]
Read Only
Bits 0-5 indicate status for DPI port communication. Bit 15 indicates when security software is
controlling the parameter.
Bit #
Factory Default Bit Values
1 = Active
0 = Not Active
x = Reserved
(1) Firmware 6.002 and later.
596 [Write Mask Cfg]
Enables/disables write access (parameters, links, etc.) for DPI ports. Changes to this parameter
only become effective when power is cycled, the drive is reset or bit 15 of [Write Mask Actv],
transitions from “1” to “0.”
DPI
P
DPI ort 6 (1
)
P
DPI ort 5
P
DPI ort 4
P
DPI ort 3
P
DPI ort 2
Por
t1
Security
0 x x x x x x x x 1 1 1 1 1 1 1
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
x x x x x x x x x 1 1 1 1 1 1 x
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit #
Factory Default Bit Values
58
Related
Parameter Name & Description
No.
Group
Programming and Parameters
File
Chapter 1
(1) Firmware 6.002 and later.
Rockwell Automation Publication 20B-UM002F-EN-P - June 2013
1 = Write Permitted
0 = Read Only
x = Reserved
090
093
126
128
213
298