Datalinks Values See page 16 for symbol descriptions 300 [Data In A1] - Link A Word 1 301 [Data In A2] - Link A Word 2 Parameter number whose value will be written from a communications device data table. Value will not be updated until drive is stopped. Refer to your communications option manual for datalink information. 302 [Data In B1] - Link B Word 1 303 [Data In B2] - Link B Word 2 Default: 0 (0 = “Disabled”) Min/Max: Units: 0/611 1 304 [Data In C1] - Link C Word 1 305 [Data In C2] - Link C Word 2 See [Data In A1] - Link A Word 1 [Data In A2] Link A Word 2. 306 [Data In D1] - Link D Word 1 307 [Data In D2] - Link D Word 2 Not available with Liquid-Cooled drives. 308 v6 [HighRes Ref] Used as a high resolution, 32 bit reference with Datalinks. –/+[Maximum Freq] or –/+[Maximum Speed] = 32767 x 65536 See [Data In A1] - Link A Word 1 [Data In A2] Link A Word 2. See [Data In A1] - Link A Word 1 [Data In A2] Link A Word 2. Default: 0 Min/Max: Units: –/+2147418112 1 DPI P DPI ort 6 (1 ) P DPI ort 5 Por DPI t 4 P DPI ort 3 P DPI ort 2 P Hos ort 1 t Sec urit y COMMUNICATIONS 310 [Data Out A1] - Link A Word 1 0 (0 = “Disabled”) Default: 311 [Data Out A2] - Link A Word 2 Min/Max: 0/611 Parameter whose value will be written to a 1 Units: communications device data table. 312 [Data Out B1] - Link B Word 1 See [Data Out A1] - Link A Word 1 [Data Out 313 [Data Out B2] - Link B Word 2 A2] - Link A Word 2. 314 [Data Out C1] - Link C Word 1 See [Data Out A1] - Link A Word 1 [Data Out 315 [Data Out C2] - Link C Word 2 A2] - Link A Word 2. 316 [Data Out D1] - Link D Word 1 See [Data Out A1] - Link A Word 1 [Data Out 317 [Data Out D2] - Link D Word 2 A2] - Link A Word 2. 595 [Port Mask Act] Read Only Bits 0-5 indicate status for DPI port communication. Bit 15 indicates when security software is controlling the parameter. Bit # Factory Default Bit Values 1 = Active 0 = Not Active x = Reserved (1) Firmware 6.002 and later. 596 [Write Mask Cfg] Enables/disables write access (parameters, links, etc.) for DPI ports. Changes to this parameter only become effective when power is cycled, the drive is reset or bit 15 of [Write Mask Actv], transitions from “1” to “0.” DPI P DPI ort 6 (1 ) P DPI ort 5 P DPI ort 4 P DPI ort 3 P DPI ort 2 Por t1 Security 0 x x x x x x x x 1 1 1 1 1 1 1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 x x x x x x x x x 1 1 1 1 1 1 x 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit # Factory Default Bit Values 58 Related Parameter Name & Description No. Group Programming and Parameters File Chapter 1 (1) Firmware 6.002 and later. Rockwell Automation Publication 20B-UM002F-EN-P - June 2013 1 = Write Permitted 0 = Read Only x = Reserved 090 093 126 128 213 298